Table 63 Error codes (part code 71 10) (continued)
Part
Error
Error Message
Code
Number
71 10
5120
The T-VOL is not selected.
71 10
5121
The data has been changed. If you select
another tab (page), the settings will be
discarded. Are you sure you want to
continue?
71 10
5122
No data has been changed.
71 10
5123
The password is invalid.
71 10
5124
You cannot select more than one
operation at a time.
71 10
5125
No target volume is selected.
71 10
6504
The number of pairs exceeds the
maximum.
71 10
7310
Unregistered error code.
71 10
731 1
The settings could not be applied.
71 10
7312
The password could not be acquired.
71 10
7313
Error details not available.
71 10
7440
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
71 10
8001
A time-out error occurred. Please wait
for the subsystem to recover to the
normal condition, and then retry the
operation.
71 10
8534
An internal logic contradiction occurred.
71 10
8568
The Emulation Type is invalid.
71 10
8658
Some settings could not be applied
normally. Refer to the error code.
71 10
8659
There is no volume.
71 10
9002
The requested operation has completed.
71 10
9005
An error occurred. Check the error code.
71 10
9101
Do you want to cancel?
71 10
9102
Do you want to apply?
71 10
9108
The option has been changed. If you
continue processing before applying the
change, the option will be reset to the
current setting. Do you want to continue
processing?
Recommended Action
Select the T-VOL, and retry the operation.
Apply the data in the Preview list. To
stop the transaction, click [OK] and
continue the operation.
Go on to the next operation.
Check the password.
Multiple volumes cannot be processed
in the operation. Process one volume at
a time.
Select the target volume.
You cannot create a pair for the
specified S-VOL. Delete the created pair,
and retry the operation.
Please contact HP Technical Support.
Wait a while, and retry the operation.
If the same error occurs despite retrying,
please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Retry the operation. If you get the same
message again, reboot the PC. If
necessary, please contact HP Technical
Support.
Please contact HP Technical Support.
Specify the volume of the supported
emulation type.
Check the error code in Preview list.
Check the contents, and retry.
The operation was ended normally.
Execute the next operation.
An error occurred during the indicated
operation. See the error code for each
operation in Preview list.
To cancel, click [OK].
Click [OK] to execute the operation.
To continue processing, click [OK].
Otherwise, click [Cancel].
Severity
Level
W
W
W
W
W
W
W
E
W
E
E
E
E
E
i
W
W
i
i
i
i
i
Part code 71 10 255

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Questions and answers

Table of Contents