HP StorageWorks P9000 - Disk Arrays Manual page 188

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58593
6505
58594
6505
58595
6505
58596
6505
58597
6505
58600
6505
58601
6505
58602
6505
58603
6505
58604
6505
58605
6505
58606
188 Message (part code group 6nnn)
Error Message
The storage system has accepted the
request normally, however the processing
requires some time. If this message is
displayed after a setting operation,
please refresh the window and check
whether the setting is reflected. If the
setting is not reflected despite refreshing
the window, please retry the operation.
The Paircreate operation failed because
the configuration of the LUSE volume was
different between the primary data
volume and the secondary data volume.
The Paircreate operation failed because
the Continuous Access Journal function
of the secondary subsystem does not
support LUSE volumes.
The operation to change the status to the
status ready for Delta resync failed
because At-Time Split was set to the
specified restore journal.
Journals cannot be added to the
extended consistency group (EXCTG),
because the controller ID of the specified
serial number is invalid.
Journals cannot be added to the
extended consistency group (EXCTG),
because Continuous Access Journal Z
function or Disaster Recovery Extended
function is not installed.
Journals cannot be added to the
extended consistency group (EXCTG),
because the additional shared memory
is not installed.
Journals cannot be added to the
extended consistency group (EXCTG),
because the number of storage systems
in the EXCTG exceeds the maximum.
Journals cannot be added to the
extended consistency group (EXCTG),
because the number of journals in the
EXCTG exceeds the maximum.
The specified journal is already
registered in the extended consistency
group (EXCTG).
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified mirror ID is
different from the mirror ID existed in the
EXCTG.
Journals cannot be deleted from the
extended consistency group (EXCTG),
because the specified EXCTG is not
registered.
Recommended Action
Wait for a while, and refresh the
window. If this message is displayed
after a setting operation, check whether
the setting is reflected. When the setting
is not reflected, retry the operation.
Check the LUSE volume configuration of
the primary data volume and the
secondary data volume.
Confirm that the Continuous Access
Journal function of the secondary storage
system supports LUSE volumes.
Check if the At-Time Split is set to the
specified restore journal with Business
Continuity Manager.
Check the controller ID of the specified
serial number.
Confirm that the Continuous Access
Journal Z function and the Disaster
Recovery Extended function are installed
in the storage system.
Please contact HP Technical Support and
install additional shared memory.
Check the number of storage systems in
the specified extended consistency group
(EXCTG).
Check the number of journals in the
specified extended consistency group
(EXCTG).
Check the number of journals in the
specified extended consistency group
(EXCTG).
Check the mirror ID of the specified
extended consistency group (EXCTG).
Check the status of the specified
extended consistency group (EXCTG).
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W

Advertisement