HP StorageWorks P9000 - Disk Arrays Manual page 77

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 31 Error codes (part code 3005) (continued)
Part
Error
Error Message
Code
Number
3005
2095
A maintenance operation is in progress.
For example:
Therefore the specified operation
cannot be executed.
3005
2200
The Concurrent Copy or the Compatible
XRC operation is in progress in the
target volumes.
3005
2201
Processing cannot be performed
because of Data Retention settings.
3005
2202
The specified volume cannot be
processed due to the effect of the
access attribute assigned by Volume
Retention.
3005
2203
Processing cannot be performed
because of Volume Security for
Mainframe settings.
3005
2204
Devices to be maintained include
journal volumes.
3005
2205
Devices to be maintained include
journal volumes.
3005
251 1
The restore operation has been failed,
because the specified LDEV was not
shredded or formatted.
3005
2512
The restore operation has been failed,
because the system cannot access the
specified LDEV.
3005
2515
One of the following is defined: a
Remote Copy pair, a Continuous
Access Journal pair, or a Continuous
Access Journal Z pair. Alternatively,
command devices defined by Business
Continuity Manager are included.
LDEV formatting is in progress
Correction Copy is in progress
Drive Copy is in progress
The CHA/DKA status is changing
The cache status is changing
Replacement of an OEM drive
microprogram is in progress
LDEV Shredding is in progress
Recommended Action
Wait for a while, and retry.
If the Concurrent Copy or the Compatible
XRC operation is in progress in the target
volumes, cancel the Concurrent Copy
job or delete a Compatible XRC pair via
the host. If the Concurrent Copy or the
Compatible XRC operation is not in
progress in the target volumes, issue the
LISTSESS and LISTDVCS commands,
check the SESSION ID No., and
terminate SESSION by means of the
TERMSESS command.
Check the settings, then retry the
operation.
Check the settings, then retry the
operation.
Check the settings, then retry the
operation.
Delete or suspend all pairs belonging to
journal volumes to be maintained.
Delete all pairs belonging to journal
volumes to be maintained.
Shred or format the specified LDEV. If
the specified LDEV is Thin Provisioning
volume (V-VOL), recover the pool first.
Please contact HP Technical Support.
Release the pair definition or delete
command devices defined by Business
Continuity Manager, and then retry the
operation.
Severity
Level
W
W
W
W
W
W
W
W
E
W
Part code 3005
77

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Questions and answers

Table of Contents