Table 21 Error codes (part code 0605) (continued)
Part
Error
Code
Number
0605
66509
0605
66510
0605
66512
0605
66517
0605
66518
0605
66520
0605
66568
W0605
66675
0605
66692
0605
66693
0605
66694
0605
66695
0605
66697
0605
66698
0605
66699
0605
66702
0605
66705
0605
66710
0605
66713
0605
66715
0605
66718
0605
66720
46
Message (part code group 0nnn)
Error Message
The total LDEV capacity defined in the
external volume exceeds the external
volume size.
The specified emulation type cannot be
used.
Specified CLPR is not mounted.
The target external volume has already
been mapped or set for mapping.
The External Path configuration of the
target external volume is not
corresponding to that of another external
volume in the same External Path Group.
Mainframe volume and intermediate
volume cannot be set because the
package for mainframe system is not
mounted.
Multiple operation tags are defined.
The syntax of the parameter is invalid.
The volume in the local storage system
cannot be operated.
A correct parameter as a data transfer
volume is not set.
A correct parameter as
RemoteCommandDevice is not set.
Specified port is not external port.
The value entered as PathMode is
outside the setting range.
The number of alternate Path definitions
that can be set to the external volume
has exceeded the maximum.
The number of LDEV definitions that can
be set to the external volume has
exceeded the maximum.
The value of External Path Group is not
set within the available range.
It is not Port number that can be
specified.
It is not set within the range where LUN
can be used.
The value of ExG is not set within the
available range.
Attribute is invalid.
It is not set within the range where CLPR
can be used.
It is not emulation type that can be
specified.
Recommended Action
Check the setting of LDEV capacity.
Check the setting of emulation type.
Check the setting of CLPR.
Check the configuration and the setting
of external volume.
Check the setting of path configuration.
Check the mounted packages.
Check the contents of the spreadsheet.
Check the syntax of parameter.
Specify the volume in an external storage
system.
Check the setting of target external
volume.
Check the setting of target external
volume.
Specify the external port.
Check the value entered as PathMode.
Check the number of alternate Path
definitions.
Check the number of LDEV definitions.
Check the setting of External Path Group.
Check the setting of Port number.
Check the setting of LUN.
Check the setting of ExG.
Check the setting of Attribute.
Check the setting of CLPR.
Check the setting of emulation type.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W