Table 55 Error codes (part code 6510) (continued)
Part
Error
Code
Number
6510
9120
6510
9121
6510
9122
6510
9127
6510
9128
6510
9155
6510
9303
6510
9305
6510
9306
6510
9308
6510
9309
6510
9327
6510
9332
6510
55036
6510
55037
6510
55038
6510
55039
206 Message (part code group 6nnn)
Error Message
The graph will be closed if you execute
the processing. Do you want to execute
the processing?
Data has been changed and the graph
has been displayed. If you continue this
operation, all the data and the graph
will become invalid. Are you sure you
want to continue this operation?
Are you sure you want to export pair
status?
Are you sure you want to close all active
graphs?
The specified volume was not found.
The history file has been updated. Select
the OK button to display the history logs
from the beginning.
There are no valid volumes.
There are no initiator ports.
The Continuous Access Journal function
is not installed in this controller. You
cannot create pairs.
You set the same path more than once.
The duplicate paths are excluded.
All paths which you set have already
been registered. This operation will
terminate because there is no path which
can be added.
The monitoring time is over, but the
history file is not fully updated yet.
This operation is not applied yet.
Too many data volumes in the journal.
Too many mirrors in the journal.
Too many mirrors in the subsystem.
You are specifying "Mirror" for the range
and trying to manipulate the same
mirror. Select only one data volume pair
in the mirror when you specify "Mirror"
for the range.
Recommended Action
To execute the processing and close the
graph, click [OK], Otherwise, click
[Cancel].
To execute this operation, click [OK],
Otherwise, click [Cancel].
To export the pair status, click [OK].
Otherwise, click [Cancel].
To close the graphs, click [OK].
Otherwise, click [Cancel].
Click [OK], then specify the correct
volume.
Click [OK].
Check the device emulation or the
definition of the SCSI path.
Set the port to Initiator before registering
the storage system.
Obtain a license for Continuous Access
Journal, then install it.
Since there are duplicated paths in the
added paths, the duplicated paths will
be eliminated. Click [OK] to continue.
Since all the added paths are redundant,
the paths cannot be added. Click [OK]
and continue.
Click [Refresh] to update the history file.
If this problem persists, please contact
HP Technical Support.
Click [OK], then continue the operation.
Check the number of data volumes in the
journal. Then delete unused data volume
pairs, or register them in another journal.
Check the number of mirrors in the
journal. Then delete unused mirrors, or
register them in another journal.
Check the number of mirrors in the
journal group, then delete unused
mirrors.
Check the range setting. If you specify
"Mirror," select only one data volume
pair in the mirror.
Severity
Level
W
W
i
W
W
i
W
W
W
W
W
i
i
W
W
W
W