Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
58503
6505
58504
6505
58508
6505
58510
6505
58530
6505
58531
6505
58532
6505
58550
6505
58552
6505
58553
6505
58560
186 Message (part code group 6nnn)
Error Message
The specified operation failed due to the
attribute or the mirror status in the
journal.
The operation failed. Please refresh the
window and retry the operation. If this
problem persists, please contact HP
Technical Support.
The Add Pair (Paircreate) operation
failed because the IO suppression mode
of the specified primary data volume was
enabled.
The Add Pair (Paircreate) operation
failed.
The combination of the specified primary
data volume number (LDKC:CU:LDEV)
and the mirror ID is the same as the
combination specified from another
primary subsystem.
Please check the mirror ID assigned to
the specified primary data volume
number (LDKC:CU:LDEV) from the
secondary subsystem.
In the current microcode version, please
specify a mirror ID different from the ID
used by an existing pair, when you
create a pair by using the same primary
data volume number (LDKC:CU:LDEV).
The capacity of the specified volume is
too small.
A journal volume cannot be added
because the combination of the
emulation types for the journal volumes
is not correct.
The Add Pair (Paircreate) operation
failed, because the emulation type is
different between the master journal and
the restore journal.
The operation to add journal volumes
failed due to the mirror status of the
specified journal.
The operation failed because the license
of the Mainframe Array Management
was not installed in the remote
subsystem.
The specified volume cannot be used as
a journal volume because it is used by
Parallel Access Volumes.
A journal volume cannot be added
because the capacity of shared memory
is insufficient.
Recommended Action
Check the attribute and the mirror status
of the journal.
If this problem persists, please contact
HP Technical Support.
Disable the IO suppression mode of the
specified primary data volume on the
Universal Volume Mgr window.
Check the mirror ID assigned to the
specified primary data volume number
(LDKC:CU:LDEV) from the secondary
storage system, and assign a mirror ID
that is not used, and retry the operation.
Check the capacity of the volume, and
specify a volume with larger capacity.
Check the emulation types of the
specified volumes.
Check the emulation type of the master
and the restore journal.
Check the mirror status of the specified
journal.
Install Mainframe Array Management in
the remote storage system or change the
access attribute of the specified primary
data volume to Read/Write.
Check whether the specified volume is
used by Parallel Access Volumes.
Please contact HP Technical Support to
install additional shared memory.
Severity
Level
W
W
W
W
W
W
W
W
W
W
E