HP StorageWorks P9000 - Disk Arrays Manual page 218

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 56 Error codes (part code 6610) (continued)
Part
Error
Code
Number
6610
59326
6610
59327
6610
59328
6610
59329
6610
59330
6610
59332
6610
59335
6610
65663
6610
65664
6610
65665
6610
65777
6610
65778
6610
65779
6610
65780
6610
69016
218
Message (part code group 6nnn)
Error Message
Specify a mirror ID other than "0" if you
create a pair ready for Delta resync.
You cannot specify [Entire] or [None] to
the Initial copy mode under the current
status of the specified master journal.
Check the status of the specified master
journal.
The journal volume cannot be deleted,
because the attribute of mirror for the
journal is "master" and the status of the
mirror is "Hold" or "Holding."
The serial number of the local DKC is
entered. Select the check box when you
add the journal of the local DKC to the
extended consistency group (EXCTG).
The local DKC cannot be specified for
the extended consistency group (EXCTG),
because the serial number other than the
local DKC is entered.
Delete the entered DKC to use the journal
of the local DKC.
A multiplatform volume is included in the
specified volumes.
The Add Pair operation cannot be
performed using multiplatform volumes.
The value of the path watch time is not
entered or is outside the range. Check
the value of the path watch time.
The specified LDKC number is incorrect.
Specify the correct LDKC number.
The specified volume is not valid for this
program product. Specify another
volume.
The specified volume is not the volume
to be monitored. Check the monitoring
setting.
The current microcode version of
DKCMAIN cannot assign remote
command devices to mirrors.
No more remote command devices can
be assigned to the specified mirror.
There are no mirrors available to assign
a remote command device.
The same mirror ID is specified in the
mirror 1 and the mirror 2 parameters.
Are you sure you want to cancel the
export?
Recommended Action
Specify a mirror ID other than 0.
Check the status of the specified master
journal.
Change the status of mirror of the journal
to "Initial," then retry the operation.
Click the check box when you add the
journal of the local DKC to the extended
consistency group (EXCTG).
Delete the entered DKC to use the journal
of the local DKC.
Confirm whether the specified volume is
a multiplatform volume. Also, confirm the
version of the microcode of the storage
system.
Check the value of the path watch time.
Specify the correct LDKC number.
Specify another volume.
Check the monitoring setting.
The microcode versions between the
DKCMAIN and the SVP might not match.
Confirm the microcode versions of the
DKCMAIN and the SVP.
Check if a remote command device was
assigned to the specified mirror.
Check if the specified journals include
mirrors available to assign a remote
command device.
Specify different mirror IDs in the mirror
1 and the mirror 2 parameters.
To stop the operation, click [OK].
To continue the operation, click [Cancel].
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
i

Advertisement

Table of Contents
loading

Table of Contents