Table 33 Error codes (part code 03022) (continued)
Part
Error
Code
Number
03022
105141
03022
105142
03022
105143
03022
105144
03022
105145
03022
105146
03022
105147
03022
105148
03022
105149
03022
105150
03022
105151
03022
105152
03022
105153
03022
105154
03022
105155
03022
105156
03022
105159
03022
105160
03022
105161
03022
105162
03022
105163
03022
105164
03022
105165
90
Message (part code group 3nnn)
Error Message
The selected LDEV has been set as a
journal volume.
The selected LDEV has been set as a
quorum disk volume.
The selected LDEV has an access
attribute setting.
An LDEV whose emmulation type is
OPEN-L or OPEN-M is selected.
An LDEV for FICON(R) Data Migration
is selected.
The target LDEV is not associated with a
pool.
The target LDEV is blocked.
The combo box is not selected.
The processing cannot continue due to
an internal logical contradiction.
Select a table.
The processing cannot continue due to
an internal logical contradiction.
An LDEV in Normal or Quick Formatting
status is selected.
The specified value is outside the range.
0 cannot be specified.
A value other than the numerical value
is specified.
The processing cannot continue due to
an internal logical contradiction.
Multiple rows are selected.
LDEVs with different emulation types are
selected.
LDEVs with different RAID levels are
selected.
LDEV names cannot be allocated to all
the selected LDEVs with the specified
numerical value of the Initial Number.
Insufficient free space to create LDEV.
LDEVs with different emulation types are
selected.
LDEVs with different RAID levels are
selected.
Recommended Action
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Execute refresh, then retry the operation.
If the same problem persists despite
retrying, please contact HP Technical
Support.
Check the setting(s).
Check the setting(s).
Execute refresh.
Specify the subject to be operated.
Execute refresh.
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Execute refresh.
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Severity
Level
W
W
W
W
W
W
W
W
E
W
E
E
W
W
W
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents