HP StorageWorks P9000 - Disk Arrays Manual page 141

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
8776
A volume cannot be used as an M-VOL
when:
it is used by Continuous Access
Journal or Continuous Access Journal
Z.
it is used by Business Copy Z or
Compatible FlashCopy.
6005
8777
Combination of MCU with RCU
controller type is not supported.
6005
8778
One side of the Cache or shared
memory on the RCU is blocked.
6005
8779
Continuous Access Synchronous is not
supported under the RCU controller type.
6005
8780
Continuous Access Synchronous Z
function is not installed in the specified
controller.
6005
8781
Continuous Access Synchronous Z
function is not installed in the specified
controller.
6005
8785
The M-VOL is defined as the expansion
volume.
6005
8786
The R-VOL is defined as the expansion
volume.
6005
8788
The specified expanded volume in the
RCU is not defined.
6005
8789
Combination of the specified expansion
volumes is not valid.
6005
8790
The specified expansion volume
(Port/GID/LUN) of the RCU is not
usable.
6005
8791
The specified M-VOL is still online from
another HOST.
6005
8792
The operation failed because the Volume
Retention function was not installed in
the specified RCU.
Install Volume Retention, and retry the
operation.
6005
8793
The Continuous Access Synchronous
function is not installed in the specified
controller(s).
6005
8794
The Continuous Access Synchronous
function is not installed in the specified
controller(s).
Recommended Action
Select another volume.
Check the controller type of the specified
MCU and RCU, then contact HP
Technical Support.
There is an invalid cache or shared
memory status on the RCU. Check the
status and recover the cache or shared
memory, then retry the operation.
Confirm the controller type of the RCU.
Install the Continuous Access
Synchronous Z in the MCU and the RCU.
Install the Continuous Access
Synchronous Z in the MCU and the RCU.
Check the volume again.
Check the volume again.
Check the Port, GID and LUN settings of
the RCU.
The combination of the specified volumes
for LUN Expansion is not valid. Verify
the parameters and retry the operation.
Confirm the status of the specified
expansion volume and microcode
version of the RCU.
Vary the concerned path offline from the
other host, then retry the operation.
Install the Volume Retention in the MCU
and the RCU, then retry the operation.
Install Continuous Access Synchronous
in the MCU and the RCU, then retry the
operation.
Install Continuous Access Synchronous
in the MCU and the RCU, then retry the
operation.
Severity
Level
W
W
E
W
W
W
W
W
W
W
W
W
W
W
W
Part code 6005
141

Advertisement

Table of Contents
loading

Table of Contents