Table 93 Error codes (part code 20123) (continued)
Part
Error
Error Message
Code
Number
20123
107004
An internal logic error occurred.
20123
107005
An internal logic error occurred.
20123
107006
An internal logic error occurred.
20123
107007
Refresh is being processed.
20123
107008
An error occurred while refreshing.
20123
107009
An error occurred while refreshing.
20123
107010
An error occurred while refreshing.
20123
10701 1
Failed to get the RMI Lock.
20123
107012
Failed to release the RMI Lock.
20123
107013
An error occurred while refreshing.
20123
107014
An error occurred while refreshing.
20123
107015
A network error occurred. It is not
possible to connect with the SVP due to
one of the following reasons.
The SVP was not ready.
An error occurred in the SVP.
A timeout error occurred while
communicating with the SVP
20123
107016
A network error occurred. It is not
possible to connect with the SVP due to
one of the following reasons.
The SVP was not ready.
An error occurred in the SVP.
20123
107017
An error occurred during SVP
processing.
Recommended Action
If the problem persists despite retrying,
please contact HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
Wait until the present processing is
completed, then retry the operation.
If the problem persists despite retrying,
please contact HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
Do the following.
This operation cannot be done while
another user is changing the
configuration. Wait for a while, then
retry the operation.
This operation cannot be done while
a task is in progress. Wait for a
while, then retry the operation. If
there is a task of waiting status,
execute [Suspend Tasks] for not to be
executed any of the tasks newly.
If the problem persists despite retrying,
please contact HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
Check the internet protocol (IP) address.
If the IP address is correct, terminate the
browser (also terminate the storage list
browser), then log it in again. If the
problem persists despite retrying, please
contact HP Technical Support.
Check the internet protocol (IP) address.
If the IP address is correct, terminate the
browser (also terminate the storage list
browser), then log it in again.
If this problem persists, please contact
HP Technical Support.
Severity
Level
E
E
E
W
E
E
E
W
E
E
E
E
E
E
Part code 20123 305