Part Code 71 10 - HP StorageWorks P9000 - Disk Arrays Manual

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 62 Error codes (part code 7105) (continued)
Part
Error
Code
Number
7105
68774
7105
68775
7105
68776
7105
68777
7105
68814
7105
68832
7105
68833
7105
68834
7105
68854

Part code 71 10

Table 63 Error codes (part code 71 10)
Part
Error
Code
Number
71 10
51 15
71 10
51 16
71 10
51 19
254 Message (part code group 7nnn)
Error Message
The SI Operation for FICON(R) Data
Migration failed, because the T-VOL of
the specified pair was used by External
Storage.
The command has been rejected,
because the S-VOL of the specified pair
is a FICON(R) Data Migration Source
Volume.
The command has been rejected,
because the T-VOL of the specified pair
is a FICON(R) Data Migration Source
Volume.
The command has been rejected,
because the specified volume is a
FICON(R) Data Migration Source
Volume.
The initialize function cannot be
executed, because a Continuous Access
Synchronous pair or a Continuous
Access Journal pair is created by using
Thin Provisioning volumes.
The command has been rejected,
because the specified CTG is used by
Snapshot.
The command has been rejected,
because the specified CTG is used by
Business Copy Z.
The command has been rejected,
because the specified CTG is used by
Business Copy.
The SI Operation for FICON(R) Data
Migration failed, because more than one
T-VOL was assigned for the specified
S-VOL.
Error Message
The T-VOL size differs from the specified
source volume size.
You cannot create another pair, because
the number of pairs exceeds the
maximum.
The S-VOL is not selected.
Recommended Action
External Storage volume cannot be used
as a T-VOL. Specify another volume.
The specified operation cannot be
executed in the current pair
configuration. Specify volumes other than
FICON(R) Data Migration Source Volume
for S-VOL, and then retry the operation.
The specified operation cannot be
executed in the current pair
configuration. Specify volumes other than
FICON(R) Data Migration source volume
for T-VOL, and then retry the operation.
The specified operation cannot be
executed to FICON(R) Data Migration
source volume. Specify a volume other
than FICON(R) Data Migration source
volume, and then retry the operation.
Delete the Continuous Access
Synchronous pair or Continuous Access
Journal pair that is using Thin
Provisioning volumes, then retry the
operation.
Use another CTG, or release the pair of
Snapshot where the specified CTG is in
use.
Use another CTG, or release the pair of
Business Copy Z where the specified
CTG is in use.
Use another CTG, or release the pair of
Business Copy where the specified CTG
is in use.
Specify the volume not used as S-VOL of
SI Operation for Mainframe Fibre Data
Migration, or retry the operation after
deleting the current pair.
Recommended Action
Check the capacity of S-VOL and T-VOL.
Specify a volume with the same capacity,
and retry the operation.
You cannot create the specified pair.
Delete the created pair, then retry the
operation.
Select the S-VOL, and retry the
operation.
Severity
Level
W
W
W
W
W
W
W
W
W
Severity
Level
W
W
W

Advertisement