Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58607
Journals cannot be deleted from the
extended consistency group (EXCTG),
because the specified journal is not
registered.
6505
58608
The Resume Pair operation failed.
Although the restore journal belongs to
an extended CT group (EXCTG), the
primary storage system does not support
the EXCTG function.
6505
58609
The timer type cannot be changed,
because the specified journal belongs to
an extended consistency group (EXCTG).
6505
58610
The parameter specified in the extended
consistency group (EXCTG) operation is
invalid.
6505
5861 1
The specified operation failed because
the microcode exchange was in progress
on the subsystem in the extended
consistency group (EXCTG).
6505
58612
The previously executed update
processing of the extended consistency
group (EXCTG) has not completed.
Please wait for a while, and then retry
the operation.
6505
58613
The command device is specified
incorrectly.
6505
58614
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified journal is not
registered.
6505
58615
Journals cannot be added to the
extended consistency group (EXCTG),
because the specified mirror ID is not
registered in the specified journal.
6505
58616
The specified journal cannot be added
to extended consistency group (EXCTG).
6505
58617
Journals cannot be added to the
extended consistency group (EXCTG),
because the attributes of the EXCTG and
the journal are different.
6505
58618
Journals cannot be added to the
extended consistency group (EXCTG),
because the timer type of the specified
journal is not "System."
6505
58620
The status of the extended consistency
group (EXCTG) is changing. Wait for a
while, refresh the window, and then retry
the operation.
Recommended Action
Check the journals in the specified
extended CT group.
Update the microcode of the primary
storage system to the version which
supports the EXCTG function.
Check if the specified journal belongs to
an extended consistency group (EXCTG).
Refresh the window, then retry the
operation. If this problem persists, please
contact HP Technical Support.
Retry the operation after the microcode
exchange completes.
Wait a while, then retry the operation.
Check whether the specified CU number
and the LDEV number indicate a
command device.
Check if the specified journal is
registered.
Check the mirror ID of the specified
journal.
Check the state of the journal in the
storage system where the specified
journal belongs to, or the installation
status of the program product.
Check the attributes of the specified
extended consistency group (EXCTG)
and the journal.
Check the timer type of the specified
journal.
Wait a while, refresh the window, then
retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
Part code 6505 189