HP StorageWorks P9000 - Disk Arrays Manual page 152

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 50 Error codes (part code 6005) (continued)
Part
Error
Code
Number
6005
58452
6005
58454
6005
58460
6005
58494
6005
58495
6005
58496
6005
58497
6005
58498
6005
58499
6005
58509
6005
58568
6005
58569
152 Message (part code group 6nnn)
Error Message
The operation failed because the
licensed capacity of Open System Array
Management on the RCU side was
insufficient or Open System Array
Management was not installed on the
RCU.
The operation failed because the
licensed capacity of Open System Array
Management on the MCU side was
insufficient or Open System Array
Management was not installed on the
MCU.
The specified M-VOL is already used as
a primary data volume for Continuous
Access Journal or Continuous Access
Journal Z. If you want to use the M-VOL
in conjunction with one of these program
products, please recreate the Continuous
Access Journal pair or the Continuous
Access Journal Z pair using a mirror ID
other than 0, and retry the operation.
A pair cannot be created because the
specified M-VOL is being used by
Snapshot.
A pair cannot be created because the
specified R-VOL is being used by
Snapshot.
A pair cannot be created because the
specified M-VOL is a virtual volume.
A pair cannot be created because the
specified R-VOL is a virtual volume.
A pair cannot be created because the
specified M-VOL is being used as a pool
volume.
A pair cannot be created because the
specified R-VOL is being used as a pool
volume.
A communication time-out error occurred
between MCU and RCU. Please wait for
a while, and then retry the operation.
A pair cannot be created because the
specified M-VOL is being shredded by
Data Retention. Retry the operation after
the shredding is completed.
A pair cannot be created because the
specified R-VOL is being shredded by
Data Retention. Retry the operation after
the shredding is completed.
Recommended Action
Check the licensed capacity of Open
System Array Management on the RCU
side, or confirm whether Open System
Array Management is installed on the
RCU. To execute this operation, purchase
a license key that allows you to use a
larger capacity or install Open System
Array Management on the RCU.
Check the licensed capacity of Open
System Array Management on the MCU
side, or confirm whether Open System
Array Management is installed on the
MCU.To execute this operation, purchase
a license key that allows you to use a
larger capacity or install Open System
Array Management on the MCU.
Use another volume, or recreate the
Continuous Access Journal pair or the
Continuous Access Journal Z pair using
a mirror ID other than 0. Then retry the
operation.
Specify another volume.
Specify another volume.
Specify another volume.
Specify another volume.
Specify another volume.
Specify another volume.
Wait a while, then retry the operation.
Confirm that the shredding has
completed in the Data Retention window,
then retry the operation.
Confirm that the shredding has
completed in the Data Retention window,
then retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Questions and answers

Table of Contents