Table 62 Error codes (part code 7105) (continued)
Part
Error
Code
Number
7105
58518
7105
58519
7105
58520
7105
58533
7105
58534
7105
58535
7105
58536
7105
58572
7105
58573
7105
58575
7105
58585
7105
58630
7105
58631
7105
58632
7105
68743
252 Message (part code group 7nnn)
Error Message
The operation failed, because the
Snapshot pair(s) existed.
The operation failed, because the
Snapshot pair(s) existed.
The operation failed, because different
versions of microcodes coexisted in the
disk subsystem.
The operation failed, because the
specified S-VOL was a journal volume.
The operation failed, because the
specified T-VOL was a journal volume.
The reserve volume setting failed
because the specified volume was a
journal volume.
The operation failed because the
specified T-VOL was a data volume of
Continuous Access Journal Z. Check the
requirements for using the volume with
Continuous Access Journal Z.
An error occurred on the DKC side. If
this problem persists, please contact HP
Technical Support.
This function is not supported.
An error occurred while connecting to
the subsystem. Please wait for a while,
and then retry the operation.
The operation failed because the CU
group of the specified volume is not
supported.
The operation failed because the
specified S-VOL was used by Delta
resync of Continuous Access Journal Z.
The operation failed because the
specified T-VOL was used by Delta
resync of Continuous Access Journal Z.
The reserve volume setting failed
because the specified volume was used
by Delta resync of Continuous Access
Journal Z.
The command has been rejected,
because Quick Format is performed on
the specified S-VOL.
Recommended Action
To continue the operation, delete all
Snapshot pair(s) and retry.
To continue the operation, delete all
Snapshot pair(s) and retry.
Replace the microcode, then retry the
operation.
Release the journal volume setting or
specify another volume.
Release the journal volume setting or
specify another volume.
Release the journal volume setting or
specify another volume.
Check the requirements for using the
volume with Continuous Access Journal
Z.
If this problem persists, please contact
HP Technical Support.
Check if the DKCMAIN and SVP
microcode versions are mismatched.
If this problem persists, please contact
HP Technical Support.
Volumes that do not belong to CU group
0 are currently not supported. Specify
another volume.
The command cannot be executed in the
current status of Continuous Access
Journal Z pair.
See the section "Sharing Business Copy
Z volumes" in the Business Copy for
Mainframe Systems User Guide for the
relation between the state of Continuous
Access Journal Z pair and the Business
Copy Z operations.
The P-VOL of Continuous Access Journal
Z pair for Delta resync cannot be
specified as S-VOL. Specify another
volume.
The P-VOL of Continuous Access Journal
Z pair for Delta resync cannot be
specified as a reserved volume.
Specify another volume.
Retry the operation after the Quick
Format has completed.
Severity
Level
W
W
E
W
W
W
W
E
E
E
W
W
W
W
W

Advertisement