Table 29 Error codes (part code 2005) (continued)
Part
Error
Code
Number
2005
1 137
2005
1 138
2005
1 182
2005
1 185
2005
1 187
2005
1 196
2005
1362
2005
1365
2005
1599
2005
1600
2005
1601
2005
1904
2005
1905
2005
1921
2005
1922
2005
1923
2005
1924
72
Message (part code group 2nnn)
Error Message
Failed to form a LUSE volume because
the number of LUSE volumes exceeds the
maximum that can be set in a disk array
subsystem.
The specified LDEV is already used for
another LUSE volume.
The capacity of LUSE volume exceeds
the maximum.
You are trying to insert in the linkage
operation including LUSE. (LDEV number
is inserted to the LDEV numbers created
in LUSE.)
You cannot expand the LU because the
host mode of the group with paths which
are defined in the LU is corresponding
to online LUSE.
The LUs cannot be combined or released
by mixing the internal and external LUs.
The LUSE volume cannot be configured
because the external volumes do not
have the same cache mode.
The different drive types cannot be
combined to form a LUSE volume.
This functionality is not available. Open
System Array Management is required.
This functionality is not available. Open
System Array Management is required.
This functionality is not available. Open
System Array Management is required.
The specified volume cannot be assigned
as an LUSE volume or a command
device, and the path of the volume
cannot be set because it is being used
as a Pool volume.
There are virtual volumes and non-virtual
volumes in the volumes specified to
compose a LUSE volume.
The specified volume is not a LUSE
volume.
LDEVs that are not normal are included
in the component of a LUSE volume.
The LDEVs to be combined are not
specified, or the number of LDEVs
exceeds the maximum number that can
be combined.
The all volumes that compose the LUSE
volume are not selected.
Recommended Action
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Check the specified contents.
Check the setting.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Correct the specified content, then retry
the operation.
Check the attributes of the external
volumes, then retry the operation.
Confirm that the different drive types
(SAS drive, SATA drive, and flash drive)
don't coexist, then retry the operation.
Install the necessary license key.
Install the necessary license key.
Install the necessary license key.
Select another volume.
Select another volume.
Check the volume, then retry the
operation.
Restore the LDEVs, then retry the
operation.
Check the setting.
Check the setting.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
W
Need help?
Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?