HP StorageWorks P9000 - Disk Arrays Manual page 138

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 50 Error codes (part code 6005) (continued)
Part
Error
Code
Number
6005
8734
6005
8735
6005
8736
6005
8737
6005
8738
6005
8739
6005
8740
6005
8741
6005
8742
6005
8743
6005
8744
138 Message (part code group 6nnn)
Error Message
The Fibre-Remote Copy function is not
installed in the specified RCU.
Invalid RCU serial number, SSID, Link
Address or Controller ID.
The specified RCU or SSID contains some
Remote Copy volume pairs.
An internal error occurred.
Remote Copy is not supported under the
MCU Controller emulation type.
NVS status of MCU is not active.
NVS status of RCU is not active.
The logical paths between the MCU and
RCU are not established.
Pinned track(s) exists on the M-VOL.
Pinned track(s) exists on the R-VOL.
The specified M-VOL condition is not
valid for Remote Copy.
Recommended Action
Install the program product key in the
RCU.
Check the serial number, SSID and link
address of the RCU, and set the correct
value. Then retry the operation. If the
same error occurs, please contact HP
Technical Support.
Delete all Remote Copy volume pairs of
the specified RCU or SSID, and retry the
operation.
Please contact HP Technical Support.
The emulation type of the MCU does not
support Continuous Access Synchronous.
If you want to use Continuous Access
Synchronous, please contact HP
Technical Support.
The MCU NVS status specified by the
host is not active. Set the NVS to "on"
for the MCU, using any attached host,
then retry the operation.
The RCU NVS status specified by the host
is not active. Use any attached host to
set the NVS to "on" for the MCU, then
retry the operation.
Check the path status between the MCU
and the RCU.
Check the status of the M-VOL tracks,
and clear the pinned tracks.
Check the status of the R-VOL tracks, and
clear the pinned tracks.
The M-VOL is not available for the
requested operation, because of one or
more of the following reasons:
The volume is blocked.
The volume is under maintenance.
The volume is copying data
(correction copy or drive copy).
The volume is in the correction access
condition.
Check the logical device status of the
specified M-VOL. If the M-VOL is either
under maintenance or copying data,
retry the operation after the process is
completed.
Severity
Level
W
W
W
E
W
W
W
W
W
W
W

Advertisement

Table of Contents
loading

Table of Contents