Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58685
Delta resync operation failed because
the specified primary data volume was
not a data volume of Continuous Access
Synchronous or Continuous Access
Synchronous Z, or the pair status of the
primary data volume was invalid.
6505
58686
The specified operation failed, because
the attribute of the journal of the remote
storage system was not "restore."
6505
58687
The status of the other mirror of the Delta
resync did not change.
6505
58688
Delta resync failed because the specified
primary data volume was not ready for
Delta resync.
6505
58689
The operation failed, because the status
of some mirrors in the master or restore
journal was invalid. Check the status of
the mirrors in the specified journal.
6505
58690
The recovery to the status ready for Delta
resync failed, because the status of the
specified primary data volume was one
of the following:
The primary data volume is being
copied; correction copy or drive copy
is in progress.
The primary data volume is in
correction access status.
The primary data volume is blocked
The primary data volume is being
maintained.
The access attribute of the primary
data volume is Read Only.
6505
58691
The specified mirror ID is already used
in the restore journal.
Specify another mirror ID.
6505
58692
The specified master journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
6505
58693
The specified restore journal cannot be
used for Delta resync, because it is
registered in the extended consistency
group (EXCTG).
Recommended Action
Check the following of the specified
primary data volume.
The volume is an M-VOL of a
synchronous pair, and the pair status
is in PAIR or Duplex when it is
referenced from the Continuous
Access Synchronous window, the
Continuous Access Synchronous Z
window, the RAID Manager, or the
Business Continuity Manager.
The volume is an R-VOL of a
synchronous pair, and the pair status
is in SSWS or Swapping when it is
referenced from the RAID Manager
or Business Continuity Manager.
Check the attribute of the journal of the
remote storage system.
If the problem persists despite retrying,
contact HP Technical Support.
Check the status of the specified primary
data volume.
Check the status of the mirrors in the
specified journal.
Check the status on the primary data
volume.
Specify another mirror ID.
Check the status of the master journal.
Check the status of the restore journal.
Severity
Level
W
W
W
W
W
W
W
W
W
Part code 6505