Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
68006
The Add Pair (Paircreate) operation
failed.
The LDKC number of the specified
primary data volume is different from the
LDKC number of the specified master
journal.
6505
68007
The Add Pair (Paircreate) operation
failed.
The LDKC number of the specified
secondary data volume is different from
the LDKC number of the specified restore
journal.
6505
68008
The Add Pair (Paircreate) operation
failed because the capacity of shared
memory of the primary subsystem was
insufficient.
6505
68009
The Add Pair (Paircreate) operation
failed because the capacity of shared
memory of the remote subsystem was
insufficient.
6505
68010
The specified journal cannot be added
to extended consistency group (EXCTG),
because the specified journal is not
registered, or the status of the specified
journal is "Initial."
6505
68013
The operation failed because the
specified volume was a Thin Provisioning
volume.
6505
68014
The operation failed because the
specified volume was a pool volume of
Thin Provisioning.
6505
68015
The operation failed because the
specified primary data volume was a
Thin Provisioning volume.
6505
68016
The operation failed because the
specified primary data volume was a
pool volume of Thin Provisioning.
6505
68017
The operation failed because the
specified secondary data volume was a
Thin Provisioning volume.
6505
68018
The operation failed because the
specified secondary data volume was a
pool volume of Thin Provisioning.
6505
68019
The secondary subsystem does not
support the LDEV number of the specified
primary data volume.
6505
68024
The operation failed because the current
microcode version does not support Delta
Resync.
Recommended Action
Check if the LDKC number of the primary
data volume and the LDKC number of
the master journal are the same.
Check if the LDKC number of the
secondary data volume and the LDKC
number of the restore journal are the
same.
Check the capacity of shared memory
of the primary subsystem.
Check the remote storage system's
shared memory capacity.
Check the status of the specified journal.
Check whether the specified volume is
a Thin Provisioning volume.
Check whether the specified volume is
a pool volume of Thin Provisioning.
Check whether the specified primary
data volume is a Thin Provisioning
volume.
Check whether the specified primary
data volume is a pool volume of Thin
Provisioning.
Check whether the specified secondary
data volume is a Thin Provisioning
volume.
Check whether the specified secondary
data volume is a pool volume of Thin
Provisioning.
Check whether the secondary subsystem
supports the LDEV number of the
specified primary data volume.
Check the connected storage system's
microcode version.
Severity
Level
W
W
E
E
W
W
W
W
W
W
W
W
W