Table 50 Error codes (part code 6005) (continued)
Part
Error
Code
Number
6005
8703
6005
8704
6005
8705
6005
8706
6005
8708
6005
8709
6005
8710
6005
871 1
6005
8712
6005
8713
6005
8714
6005
8715
6005
8717
136 Message (part code group 6nnn)
Error Message
The specified number of Paths is less than
the Minimum number of Paths on RCU
Option screen.
The specified number of paths is less
than the minimum number of paths on
the RCU option screen due to a
communication error between the MCU
and the RCU.
The path could not be deleted due to a
communication error between MCU and
RCU.
Parameter specified by Remote Copy
operation is invalid.
The pair status of the R-VOL is not valid.
Remote Copy operation was rejected.
The pair status of the specified volume
is not valid.
The Port, GID, LUN, CU, or LDEV number
of the specified volume is incorrect.
The operation was rejected due to a
'FREEZE' state.
The port group already exists on the
specified port.
An internal error occurred.
Invalid number of paths.
Invalid Destination Link Address.
Recommended Action
The number of paths is less than the
minimum number specified on the RCU
Option dialog box. Check the number
of paths, establish the minimum number
of paths, and retry the operation.
Check the paths status and reestablish
the paths.
Either a communication error occurred
between the MCU and the RCU, or the
CHA has become blocked. Please
contact HP Technical Support.
Specify a correct value.
Check the pair status for Continuous
Access Synchronous. If the requested
R-VOL is in a permissible status, please
retry the operation.
All channel adapters are not active for
Continuous Access Synchronous. Please
contact HP Technical Support.
The pair status does not permit this
operation. Verify the pair status, and if
the operation is permitted retry.
Check if the specified Port, GID, LUN,
CU, or LDEV number exists in the storage
system.
If this was a path operation retry after
the problem has been fixed.
If this was a pair operation, retry after
the paths have been recovered. Two
ways to recover paths are:
(a) Execute ESTPATH from the host
console, or
(b) First delete the path(s) from the SVP,
then re-add them.
The port type could not be changed
because the port group was set in the
specified package. Delete the group
setting, then change the port type.
Please contact HP Technical Support.
The specified number of paths is not
within the acceptable path range of 0 to
4. Verify the number of paths and retry
the operation.
The specified logical address must be
either 00 or 01. Check the logical
address and retry the operation.