Table 65 Error codes (part code 8105) (continued)
Part
Error
Code
Number
8105
1007
8105
1009
8105
1010
8105
1018
8105
1022
8105
1023
8105
1024
8105
1025
8105
1059
8105
1061
8105
1063
8105
1064
8105
1065
260 Message (part code group 8nnn)
Error Message
Failed to remove the path. The specified
path is the last path of the volumes used
for Remote Copy, Business Copy, Auto
LUN, or Snapshot.
The emulation type of the volumes is not
for open systems, or the volumes are not
mounted.
An error occurred during SVP
processing.
The specified port does not exist. Or the
specified port type is not Fibre port.
Invalid host mode.
The specified fiber address is wrong.
Invalid Fibre topology information.
The specified LU path does not exist.
LUN security setting has been made to
a non-Fibre port. LUN security is a
function of LUN Manager.
Security Switch Off operation and path
adding operation cannot be performed
simultaneously.
The specified WWN is already in use.
You are trying to register the same
WWN that is already registered.
The specified host name or the host
group name is already registered. (The
host name and the host group name
cannot be the same.)
Recommended Action
Check the setting.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
If this problem persists, please contact
HP Technical Support.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Correct the specified content, and issue
the request again. (Currently, Bad Value
Send report in Set Response.)
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again
Check the specified contents, then retry
the operation.
You are trying to perform LUN Security
operation for a port where LUN Security
function is invalid. The error does not
occur normally because it cannot be
modified in the window. In the unlikely
event that this error occurs, please
contact HP Technical Support.
Check the specified contents, then retry
the operation.
The configuration information has been
changed already. Check the settings,
and request the configuration information
setting again.
Correct the specified contents, and
request the setting of the configuration
information again.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
W