HP StorageWorks P9000 - Disk Arrays Manual page 234

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 59 Error codes (part code 7005) (continued)
Part
Error
Code
Number
7005
58493
7005
58520
7005
58533
7005
58534
7005
58535
7005
58536
7005
58572
7005
58573
7005
58574
7005
58575
7005
58576
7005
58579
7005
58582
7005
58583
7005
58584
234 Message (part code group 7nnn)
Error Message
The PCB required for this operation is
not mounted. Check the subsystem
configuration.
The operation failed, because different
versions of microcodes coexisted in the
disk subsystem.
The operation failed, because the
specified P-VOL was a journal volume.
The operation failed, because the
specified S-VOL was a journal volume.
The reserve volume setting failed
because the specified volume was a
journal volume.
The operation failed because the
specified S-VOL was a data volume of
Continuous Access Journal. Check the
requirements for using the volume with
Continuous Access Journal.
An error occurred on the DKC side. If
this problem persists, please contact HP
Technical Support.
This function is not supported.
An error occurred while connecting to
the subsystem. Please wait for a while,
and then retry the operation.
An error occurred while connecting to
the subsystem. Please wait for a while,
and then retry the operation.
A communication time-out error occurred
in the disk subsystem. Please wait for a
while, and then retry the operation.
The operation failed, because the
specified volume is being shredded by
Data Retention. Retry the operation after
the shredding is completed.
The command has been rejected,
because the specified S-VOL is used as
P-VOL of Snapshot or the specified MU
number is already used.
The operation failed because the volume
was shared by a Snapshot pair.
The operation failed because the volume
was shared by a Snapshot pair in COPY
(RS-R) status.
Recommended Action
Mount the required PCB, then retry the
operation.
Replace the microcode, then retry the
operation.
Release the journal volume setting, or
specify another volume.
Release the journal volume setting, or
specify another volume.
Release the journal volume setting, or
specify another volume.
Check the requirements for using the
volume with Continuous Access Journal.
An error occurred on the DKC side. If
this problem persists, please contact HP
Technical Support.
Check if the DKCMAIN and SVP
microcode versions are mismatched.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Confirm that the shredding has
completed in the Data Retention window,
then retry the operation.
The specified command cannot be
executed with the current pair
composition.
See the section about the interoperability
with other products and functions and
the Business Copy described in the HP
StorageWorks P9000 Snapshot User
Guide for the condition of sharing the
volumes between Snapshot and Business
Copy.
To continue the operation, release the
Snapshot setting.
Check the conditions for using Business
Copy in conjunction with Snapshot.
Severity
Level
E
E
W
W
W
W
E
E
E
E
E
W
W
W
W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents