HP StorageWorks P9000 - Disk Arrays Manual page 185

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58458
A different mirror ID has already been
registered in the specified master journal.
Specify the same mirror ID, because only
one mirror ID can be registered in one
journal.
6505
58459
The Add Pair operation or the Resume
Pair operation failed because the
specified secondary data volume was
used by Compatible FlashCopy.
6505
58485
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was one of the following:
the specified volume was a P-VOL of
Snapshot and was in Reverse Copy
status.
the specified volume was an S-VOL
of Snapshot.
6505
58486
The Paircreate operation failed because
the specified primary data volume was
a V-VOL for Snapshot.
6505
58487
The Paircreate operation failed because
the specified primary data volume was
a Pool-VOL.
6505
58490
Only the pair option of the primary data
volume was updated. Failed to update
the pair option of the secondary data
volume.
6505
58500
The Add Pair (Paircreate) operation
failed because the Continuous Access
Journal or the Continuous Access Journal
Z function of the secondary storage
system does not support external
volumes.
6505
58501
The Paircreate operation failed because
the Continuous Access Journal function
of the secondary storage system does
not support Data Retention VMA.
6505
58502
The operation failed because the
capacity of the secondary storage system
has exceeded the licensed capacity of
Open System Array Management.
Recommended Action
Specify the same mirror ID as the
registered mirror ID, then retry the
operation.
From the Compatible FlashCopy
window, check the status of the specified
secondary data volume.
Confirm the state of the specified primary
data in the Snapshot window.
Check the state of the specified primary
data volume.
Confirm the status of the specified
primary data volume.
A communication error between the
primary and the secondary storage
systems occurred, or the microcode of
the secondary storage system does not
support the change pair option function.
Check the main microcode of the
secondary storage system, and contact
HP Technical Support to confirm whether
the microcode supports the change pair
option function. If the microcode supports
the function, contact HP Technical
Support because a communication error
might have occurred.
Check the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
or the Continuous Access Journal Z
function supports external volumes.
Check the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
function supports Data Retention VMA.
Confirm the licensed capacity of the
Open System Array Management of the
secondary storage system. To perform
the specified operation, purchase a
license key that allows you to use a
capacity larger than the current capacity.
Severity
Level
W
W
W
W
W
E
W
W
W
Part code 6505 185

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Questions and answers

Table of Contents