Table 46 Error codes (part code 5205) (continued)
Part
Error
Code
Number
5205
2004
5205
201 1
5205
2024
5205
2025
5205
2026
5205
2027
5205
2028
5205
2029
5205
2030
5205
3002
5205
3003
5205
5013
5205
5099
5205
5203
5205
5504
5205
5505
5205
5506
5205
5507
5205
5510
5205
6000
120 Message (part code group 5nnn)
Error Message
An error occurred during SVP
processing.
The disk subsystem is busy. Please wait
for a while, and then retry the operation.
The controller detected the blockade
location.
The controller detected the blockade
location.
The controller detected the blockade
location.
The controller detected the blockade
location.
The controller detected the blockade
location.
A data transfer failure was detected.
A data transfer failure was detected.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
This functionality is not available because
Auto LUN is not installed.
The specified volume cannot be migrated
because it is used as S-VOL in the
following status.
A volume of Continuous Access
Synchronous, or Continuous Access
Synchronous Z in the Pending status.
The volume(s) is already being used by
Remote Copy.
The specified volume cannot be migrated
because it is used as P-VOL in the
following status.
A volume of Continuous Access
Synchronous or Continuous Access
Synchronous Z in the Pending status.
The specified volume is not defined as
the target volume of Auto LUN.
This function has already executed.
An error occurred during SVP
processing.
Recommended Action
If this problem persists, please contact
HP Technical Support.
Release the Remote Copy Pair.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
Install the required program product.
For the relation between Continuous
Access Synchronous or Continuous
Access Synchronous Z and Auto LUN,
see the description of Auto LUN with
Continuous Access Synchronous and
Continuous Access Journal V-VOLs in the
Auto LUN User Guide..
Please Release the Remote Copy Pair.
For the relation between Continuous
Access Synchronous or Continuous
Access Synchronous Z and Auto LUN,
see the description of Auto LUN with
Continuous Access Synchronous and
Continuous Access Journal V-VOLs in the
Auto LUN User Guide..
Retry the operation.
Wait for a moment and retry.
If this problem persists, please contact
HP Technical Support.
Severity
Level
E
E
E
E
E
E
E
E
E
E
E
E
E
W
W
W
W
W
E
E
Need help?
Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?