Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
58586
The operation failed because the host
did not allow the specified R-VOL to be
used as an R-VOL.
6005
58640
The Add Pair operation failed.
The volume pair cannot be created with
Time Stamp set, because RCU does not
support 4x4x4 cascade function.
6005
58712
The licensed capacity of Continuous
Access Synchronous or Continuous
Access Synchronous Z on the RCU is
insufficient.
6005
58714
The licensed capacity of Continuous
Access Synchronous or Continuous
Access Synchronous Z on the MCU is
insufficient.
6005
65740
The configuration changing processes
are conflicting at DKC.
6005
6801 1
The operation failed because the
specified M-VOL was used as a Thin
Provisioning volume.
6005
68012
The operation failed because the
specified R-VOL was used as a Thin
Provisioning volume.
6005
68020
"Maximum Initial Copy Activities (CU)"
cannot be changed to Enable or Disable,
because there are pairs in COPY or
Pending status.
6005
68022
The specified M-VOL is used as a data
volume of Continuous Access Journal or
Continuous Access Journal Z. The
operation failed because Disaster
Recovery Extended function is not
installed in the MCU.
6005
68023
The specified R-VOL is used as a data
volume of Continuous Access Journal or
Continuous Access Journal Z. The
operation failed because Disaster
Recovery Extended function is not
installed in the RCU.
Recommended Action
Check whether the number of the
specified R-VOL is correct or the status
of the usage of the host to the specified
R-VOL.
Check whether the version of DKC
microcode of RCU supports the 4x4x4
cascade function. If the version does not
support the 4x4x4 cascade function,
update the microcode of RCU to the
version that supports the function, or retry
the Add Pair operation with the setting
that does not transfer Time Stamp.
Check the licensed capacity of these
program products.
See the user's guides of Continuous
Access Synchronous or Continuous
Access Synchronous Z for details of the
licensed capacities.
Check the licensed capacity of these
program products.
See the user's guides of Continuous
Access Synchronous or Continuous
Access Synchronous Z for details of the
licensed capacities.
Check if the configuration changing
process by RAID Manager, Auto LUN,
or Quick Restore is not in the operation,
then retry the operation.
Check whether the specified R-VOL is a
Thin Provisioning volume.
Check whether the specified R-VOL is a
Thin Provisioning volume.
Confirm that no pairs are in COPY or
Pending status, then retry the operation.
Install Disaster Recovery Extended
function to the MCU.
Install Disaster Recovery Extended
function to the RCU.
Severity
Level
W
W
W
W
W
W
W
W
W
W
Part code 6005 153
Need help?