Part Code 6007 - HP StorageWorks P9000 - Disk Arrays Manual

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 50 Error codes (part code 6005) (continued)
Part
Error
Code
Number
6005
68893
6005
68894
6005
68899
6005
68900
6005
78001
6005
78002

Part code 6007

Table 51 Error codes (part code 6007)
Part
Error
Code
Number
6007
5074
6007
6000
6007
6002
6007
6012
6007
6022
6007
6023
6007
6024
6007
6036
6007
8001
Error Message
The operation failed, because the
following program products were not
installed in the RCU.
Continuous Access Synchronous
The operation failed, because the
quorum disk registered in the specified
quorum disk ID was not registered in the
quorum disk ID of RCU, or it was
registered in the other quorum disk ID.
The operation failed, because a quorum
disk was not registered in the specified
quorum disk ID.
The operation failed, because the
specified quorum disk ID was different
from the one used by the specified pair.
The operation failed, because the current
microcode version does not support the
capacity of the specified M-VOL.
The operation failed, because the current
microcode version does not support the
capacity of the specified R-VOL.
Error Message
Continuous Access Synchronous or
Continuous Access Synchronous Z is not
installed.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
The SVP is busy. Please wait for a while,
and then retry the operation.
The SVP is busy. Please wait for a while,
and then retry the operation.
An error occurred during SVP
processing.
An error occurred during SVP
processing.
A time-out error occurred.
Recommended Action
Install the necessary program products
in the RCU.
Confirm the quorum disk ID, serial
number of RCU, and quorum disk.
Confirm the quorum disk ID status.
Confirm the quorum disk ID of the
specified pair.
Check the microcode version of the
storage system.
Check the microcode version of the
storage system.
Recommended Action
Install Continuous Access Synchronous
or Continuous Access Synchronous Z.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If the same problem persists despite
retrying, please contact HP Technical
Support.
If the same problem persists despite
retrying, please contact HP Technical
Support.
If this problem persists, please contact
HP Technical Support.
If this problem persists, please contact
HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
Severity
Level
W
W
W
W
W
W
Severity
Level
W
E
E
E
W
W
E
E
E
Part code 6007 157

Advertisement

Table of Contents
loading

Table of Contents