Table 26 Error codes (part code 01022) (continued)
Part
Error
Code
Number
01022
105087
01022
105088
01022
105089
01022
105090
01022
105091
01022
105093
01022
105094
01022
105204
01022
105207
01022
105208
01022
105209
01022
105210
01022
105252
01022
105253
01022
105277
64
Message (part code group 1nnn)
Error Message
The LUN ID cannot be set, because the
value is outside the range.
The table column is not selected.
The number of LUNs that can be set to
the specified port has exceeded the
maximum.
The specified LDEV and an LDEV with
LUN registered to the specified host
group have the same ID.
The number of selected host groups that
can be set exceeds the maximum value.
The attribute of the specified port is
neither Target nor RCU Target.
The length of the HBA WWN is
incorrect.
The operation cannot be executed
because the program product is not
installed or there is no editorial
permission to the user.
The number of LUNs that can be set to
the specified port has exceeded the
maximum.
The specified host cannot be added
because the HBA WWN or the host
name is used in the same port, or, it is
used in the item that has been moved in
the [Selected Host Groups] table.
The host mode is left blank.
There are blank items in the Host Mode
Options Table.
Other than the Host Mode 00 [Standard]
has been set to the Host Group #00 of
the specified port.
[Enabled] has been set to the Host Mode
Option for the Host Group #00 of the
specified port.
Some LDEVs or Host Groups that are not
available for LUN path setting are
excluded from the choices.
Recommended Action
Check the setting(s).
Check the check boxes for the items that
you want to change, then retry the
operation.
Check the setting(s).
Check the setting(s).
Check the setting(s).
Check the setting(s).
Specify the HBA WWN with 16 digits
in hexadecimal.
Install the program product. Or, execute
the operation with the user who has an
editorial permission, or set the editorial
permission to the user.
Check the setting(s).
Check the setting(s).
Set the item that is left blank, then retry
the operation.
Set the item that is left blank, then retry
the operation.
To change the setting from Target/RCU
Target to Initiator/External, set only 00
to the host group of the target port, set
the host mode to 00 [Standard], and set
all of the host mode options to Disable.
To change the setting from Target/RCU
Target to Initiator/External, set only 00
to the host group of the target port, set
the host mode to 00 [Standard], and set
all of the host mode options to Disable.
Click [OK], then continue the operation.
Severity
Level
W
E
W
W
W
W
W
W
W
W
W
W
W
W
W