Part Code 6507 - HP StorageWorks P9000 - Disk Arrays Manual

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 53 Error codes (part code 6505) (continued)
Part
Error
Code
Number
6505
68887
6505
68888
6505
78003
6505
78004
6505
78050
6505
78051
6505
78066

Part code 6507

Table 54 Error codes (part code 6507)
Part
Error
Code
Number
6507
5036
6507
6012
6507
6036
Error Message
The operation failed, because the
specified primary data volume was as
follows:
This volume was used as T-VOL of
Compatible FlashCopy.
This volume was used as M-VOL of
Continuous Access Synchronous Z,
and it was suspended by either of the
following settings:
It was a pair of synchronous
consistency group.
It was a pair that the "Cylinder" was
set to "Difference Management."
The operation failed, because the
specified "primary data volume" was
used as T-VOL of Compatible FlashCopy
that might be in the abnormal state due
to a failure.
The specified journal cannot be used.
The specified consistency group cannot
be used.
The operation failed because the
specified capacity of the primary data
volume is not supported by the current
microcode version.
The operation failed because the
specified capacity of the secondary data
volume is not supported by the current
microcode version.
The operation failed. The Mainframe
Fibre CHA of RCU is not mounted or all
the Mainframe Fibre CHA are blocked.
Error Message
Two or more commands which were not
able to be processed were demanded.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
Recommended Action
Confirm the relationship status of
Compatible FlashCopy and the pair
status of Continuous Access Synchronous
Z.
Confirm the relationship status of the
Compatible FlashCopy.
Check the specified journal.
Check the specifed consistency group.
Check the specified capacity of the
primary data volume and the current
microcode version.
Check the specified capacity of the
secondary data volume and the current
microcode version.
Please contact HP Technical Support.
Recommended Action
Check the settings, and retry the
operation.
If the problem persists despite retrying,
please contact HP Technical Support.
If the problem persists despite retrying,
please contact HP Technical Support.
Severity
Level
W
W
W
W
W
W
E
Severity
Level
W
E
E
Part code 6507 203

Advertisement

Table of Contents
loading

Table of Contents