HP StorageWorks P9000 - Disk Arrays Manual page 173

Hp storageworks p9000 remote web console messages (av400-96351, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
8936
The Paircreate (Add Pair) operation
failed. The microcode version of the
specified secondary subsystem does not
support Remote Copy with NAS volumes.
6505
8944
The specified secondary data volume is
unusable because of the access attribute
changed by Data Retention.
6505
8947
The external volume that is mapped to
an internal volume is connected to the
port.
6505
8948
The specified port is receiving I/O
requests.
6505
8949
An internal error occurred.
6505
8950
An internal error occurred.
6505
8977
The Add Pair (Paircreate) operation
failed because the specified secondary
data volume was used by XP Flex Copy.
6505
8980
The operation failed because the
licensed capacity of Mainframe Array
Management on the remote subsystem
was exceeded.
6505
56524
This function cannot be used by the
storage partition administrator.
6505
56535
Processing in progress. Please wait for
a while, and then retry the operation.
6505
58005
Too many requests. Please reduce the
number of requests to be processed at
one time. After that, please retry the
operation.
6505
58006
Invalid parameter (LDEV number).
6505
58007
Invalid parameter (Journal number).
6505
58008
The command was rejected by the
subsystem because the command is
unknown.
6505
58009
No more remote subsystems can be
registered.
6505
58010
Invalid parameter (path group ID).
6505
5801 1
The specified operation failed due to the
mirror status of the journal.
6505
58012
Invalid parameter (number of initial copy
activities).
6505
58013
The specified volume does not exist or
is unusable.
6505
58014
Pinned slot(s) exists.
Recommended Action
Check the microcode version of the
secondary storage system.
Check the access attribute of the
specified secondary data volume.
Cancel the definition of the external
volume, and retry the operation.
Stop I/O operations, and retry.
Check the SSB log, then contact HP
Technical Support.
Check the SSB log, then contact HP
Technical Support.
Check the status of the specified
secondary data volume.
Confirm the licensed capacity of the
Mainframe Array Management of the
remote storage system. To perform the
specified operation, purchase a license
key that allows you to use a capacity
larger than the current capacity.
Please contact HP Technical Support.
Processing in progress. Wait a while,
then retry the operation.
Reduce the number of requests to be
processed at one time. Then retry the
operation.
Check the specified LDEV number.
Check the specified journal number.
Please contact HP Technical Support.
Reduce the number of registered remote
storage systems, then retry the operation.
Check the specified path group ID.
Refresh the window, and check the
mirror status of the journal.
Check the specified number of initial
copy activities.
Check the status of the specified volume.
Please contact HP Technical Support.
Severity
Level
W
W
W
W
E
E
W
W
E
W
W
W
W
E
W
W
W
W
W
E
Part code 6505 173

Advertisement

Table of Contents
loading

Table of Contents