Table 50 Error codes (part code 6005) (continued)
Part
Error
Error Message
Code
Number
6005
8892
R-VOLs exist on the RCU port. Are you
sure you want to continue this operation?
6005
8893
An internal error occurred.
6005
8894
Pending background data exists on the
MCU.
6005
8895
Pending background data exists on the
RCU.
6005
8896
A parameter error occurred.
6005
8897
LUs exist on the port.
6005
8898
Pending data exists on the port.
6005
8899
An internal error occurred.
6005
8900
An error occurred during the port
change.
6005
8901
An error occurred during the port
change.
6005
8902
An error occurred during the port
change.
6005
8903
Unknown Error Code.
6005
8904
No more space is left in MCU for
differential management.
6005
8905
The extended SM is not equipped in
MCU.
6005
8906
No more space is left in RCU for
differential management.
Recommended Action
If you want to continue this operation,
click [Yes]. If not, click [No].
Please contact HP Technical Support.
Stop the jobs on the host, then retry the
operation.
Stop the jobs on the host, then retry the
operation.
Specify a correct value.
Delete the LUs defined on the specified
port, then retry the operation.
Wait for a while, then retry the
operation.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
If the extended shared memory (SM #2)
is not installed in MCU, install the shared
memory to MCU according to the
installation instruction of the extended
shared memory for remote copy
("Shared Memory Size Configuration"
dialog box), then create a pair.
If SM #2 is installed in MCU, you cannot
create any more pairs because the
number of pairs has already reached the
maximum that can be created by the
system.
Install the shared memory to the MCU
with the installation instruction of
expansion SM for remote copy (Shared
Memory Size Configuration).
If the extended shared memory (SM #2)
is not installed in RCU, install the shared
memory to RCU according to the
installation instruction of the extended
shared memory for remote copy
("Shared Memory Size Configuration"
dialog box), then create a pair.
If SM #2 is installed in RCU, you cannot
create any more pairs because the
number of pairs has already reached the
maximum that can be created by the
system.
Severity
Level
W
E
W
W
W
W
W
E
E
E
E
E
E
E
E
Part code 6005