Table 61 Error codes (part code 7010) (continued)
Part
Error
Error Message
Code
Number
7010
51 18
The MU number was not selected.
7010
51 19
No P-VOL is selected.
7010
5120
No S-VOL is selected.
7010
5121
The data has been changed. If you select
another tab (page), the settings will be
discarded. Are you sure you want to
continue?
7010
5122
No data has been changed.
7010
5123
The password is invalid.
7010
5124
You cannot select more than one
operation at a time.
7010
5125
No target volume is selected.
7010
5126
You cannot create another L2 pair,
because the number of L2 pairs exceeds
the maximum.
7010
5127
The specified MU number is invalid.
Select another MU number.
7010
6504
The number of L1 pairs exceeds the
maximum.
7010
6505
The number of L2 pairs exceeds the
maximum.
7010
7310
Unregistered error code.
7010
731 1
The settings could not be applied.
7010
7312
The password could not be acquired.
7010
7313
Error details not available.
7010
7440
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
7010
8534
An internal logic contradiction occurred.
7010
8568
The Emulation Type is invalid.
7010
8658
Some settings could not be applied
normally. Refer to the error code.
7010
8659
The PCB required for this operation is
not mounted. Check the subsystem
configuration.
7010
9002
The request operation has completed.
Recommended Action
Select MU number.
Select P-VOL, and operate.
Select S-VOL, and operate.
Apply the data in the Preview list. To
stop the transaction, click [OK] and
continue the operation.
Go on to the next operation.
Check the password.
Multiple volumes cannot be processed
in the operation. Process one volume at
a time.
Select the target volume.
You cannot create L2 pair for the
specified P-VOL. Delete the created L2
pair, and retry the operation.
Select the other MU number.
You cannot create L1 pair for the
specified P-VOL. Delete the created L1
pair, and retry the operation.
You cannot create L2 pair for the
specified P-VOL. Delete the created L2
pair, and retry the operation.
Please contact HP Technical Support.
Wait a while, and retry the operation.
If the same error occurs despite retrying,
please contact HP Technical Support.
Please contact HP Technical Support.
Please contact HP Technical Support.
If this problem persists please contact HP
Technical Support.
Please contact HP Technical Support.
Specify the volume of the supported
emulation type.
Check the error code in the Preview list.
Mount the required PCB, then retry the
operation.
The operation was ended normally.
Execute the next operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
W
E
W
E
E
E
i
i
W
W
i
Part code 7010 239
Need help?
Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?
Questions and answers