Table 53 Error codes (part code 6505) (continued)
Part
Error
Error Message
Code
Number
6505
58272
A Concurrent Copy operation is in
progress on the specified secondary data
volume.
6505
58273
Either of the following settings is set to
the specified secondary data volume by
the Volume Security for Mainframe
function.
The volume belongs to the access
group or the pool group.
The setting does not allow the volume
to be used as a secondary data
volume.
6505
58275
The specified restore journal is not
registered.
6505
58276
The specified secondary data volumes
cannot be paired with another volume,
because the secondary data volume is
used as a journal volume.
6505
58277
The specified secondary data volume is
not registered in the specified journal.
6505
58278
The specified restore journal is not
registered.
6505
58279
The emulation type of the specified
secondary data volume and the restore
journal volume is incorrect due to one of
the following reasons:
The emulation type is not supported.
The combination of emulation types
within the journal is incorrect.
The combination of emulation types
between the journal volumes of the
master and restore journals is
incorrect.
The emulation types of the primary
and secondary data volumes are not
the same.
6505
58280
The specified secondary data group is
already registered.
6505
58281
No more pairs can be registered in the
specified restore journal.
6505
58282
The specified secondary data volume is
already registered in another journal.
6505
58283
The specified secondary data volume
cannot be deleted, because the volume
is already registered in another journal.
6505
58284
An internal error occurred.
6505
58285
No more pairs can be registered
because the number of pairs will exceed
the maximum.
Recommended Action
Check the status of the specified
secondary data volume.
Use Volume Security for Mainframe to
check the status of the specified
secondary data volume.
Check the specified restore journal.
Check the status of the specified
secondary data volume.
Check the data volumes in the specified
secondary journal.
Check the status of the specified restore
journal.
Check the emulation type of the specified
secondary data volume or the restore
journal volume.
Check the status of the specified
secondary data volume.
Check the number of pairs in the
specified restore journal.
Identify the journal where the specified
secondary data volume is registered.
Identify the journal where the specified
secondary data volume is registered.
Please contact HP Technical Support.
Check the number of pairs.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
E
W