Table 62 Error codes (part code 7105) (continued)
Part
Error
Error Message
Code
Number
7105
68744
The command has been rejected,
because Quick Format is performed on
the specified T-VOL.
7105
68745
FICON(R) Data Migration Source Volume
is specified as a T-VOL. FICON(R) Data
Migration Source Volume cannot be used
as a T-VOL.
7105
68746
The command has been rejected
because the pair uses FICON(R) Data
Migration Source Volume.
7105
68747
The command has been rejected,
because the FICON(R) Data Migration
source volume is used in the specified
pair, and T-VOL is used with the other
program products.
Continuous Access Synchronous Z
Continuous Access Journal Z
Compatible Flash Copy(R) V2
Mainframe Array Management
7105
68767
The SI Operation for FICON(R) Data
Migration failed, because the specified
pair consisted of an S-VOL other than a
FICON(R) Data Migration Source
Volume, or a T-VOL that is a FICON(R)
Data Migration Source Volume.
7105
68768
The SI Operation for FICON(R) Data
Migration failed, because the pair status
of the specified pair was not SIMPLEX or
DUPLEX.
7105
68769
The SI Operation for FICON(R) Data
Migration failed, because the pair status
of the specified pair was not
Suspend(Mig.).
7105
68770
The SI Operation for FICON(R) Data
Migration failed, because the Cache
Residency Z setting was set in the T-VOL
of the specified pair.
7105
68771
The SI Operation for FICON(R) Data
Migration failed, because the Volume
Retention setting was set in the T-VOL of
the specified pair.
7105
68772
The SI Operation for FICON(R) Data
Migration failed, because the T-VOL of
the specified pair was used by
Continuous Access Journal Z.
7105
68773
The SI Operation for FICON(R) Data
Migration failed, because the T-VOL of
the specified pair was used by
Continuous Access Synchronous Z.
Recommended Action
Retry the operation after the Quick
Format has completed.
FICON(R) Data Migration source volume
cannot be used as a T-VOL. Use other
volumes.
The specified pair cannot be operated
because the pair uses FICON(R) Data
Migration source volume.
Cancel the setting to use the T-VOL with
the other program products, then retry
the operation.
The SI Operation for FICON(R) Data
Migration cannot be executed in the
current pair configuration. Specify
FICON(R) Data Migration source volume
for S-VOL, and specify volumes other
than FICON(R) Data Migration source
volume for T-VOL.
The SI Operation for FICON(R) Data
Migration cannot be executed in the
current pair status. Change the status of
the pair to SIMPLEX or DUPLEX, then retry
the operation.
The SI Operation for FICON(R) Data
Migration cannot be executed in the
current pair status. Change the status of
the pair to Suspend(Mig.), then retry the
operation.
Release the Cache Residency Z setting
in the T-VOL.
Release the Volume Retention setting in
the T-VOL or specify another volume, and
then retry the operation.
Delete the Continuous Access Journal Z
pair or specify another volume, and then
retry the operation.
Delete the Continuous Access
Synchronous Z pair or specify another
volume, and then retry the operation.
Severity
Level
W
W
W
W
W
W
W
W
W
W
W
Part code 7105 253
Need help?
Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?