Control Method Selection; Parameter Settings For Operation Without The Brake Sequence; Setting The Direction Of Motor Rotation - YASKAWA CR700 Technical Manual

Hide thumbs Also See for CR700:
Table of Contents

Advertisement

Note:
If the keypad does not show the Initial Setup screen, or shows a different screen, select [Initial Setup] from the Main Menu to show the
Initial Setup screen.
1.
Make the initial settings for each item.
A - Language Selection
B - Set Date/Time
Note:
If you select [Yes] from the [Show Initial Setup Screen] setting, the keypad will show the Initial Setup screen each time the
drive is energized. If you select [NO], the keypad will not show the Initial Setup each time the drive is energized, starting with
the next time.
2.
Push
(Home).
The display shows the HOME screen.

Control Method Selection

After energizing the drive, select the control method most appropriate for the application first. Encoder options are
necessary for CL-V/f control and CLV control.
Control Method
V/f Control
Closed Loop V/f control
Open Loop Vector control
Closed Loop Vector control
Advanced Open Loop Vector control
Control Method Type and Corresponding Features on page 26
Refer to
each control method.

Parameter Settings for Operation Without the Brake Sequence

If you operate the drive without the brake sequence, set S1-54 = 0 [Brake Sequence Selection = Disabled].

Setting the Direction of Motor Rotation

For hoist applications, wire the drive so that the Forward Run command hoists the load, and the Reverse Run
command lowers the load. If the machine does not move this way, crane software functions and performance will
be reversed, making it impossible to take full advantage of the drive performance and capabilities.
Follow the procedure below to confirm the direction of motor rotation.
• Check the order of the U, V, and W phase output from the drive by checking the voltage (looking at the motor
from the load side, most motors will rotate clockwise as the forward direction).
Check the direction of motor rotation as it corresponds to the U, V, and W phase order.
• Check if b1-14 = 0 [Phase Order Selection = Standard] when operating the motor to hoist the load with the
phase order U, V, and W.
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
3.5 Items to Check before Starting Up the Drive
C - Show Initial Setup Screen
Table 3.6 Control Method Selection
A1-02 Setting
0
1
2
3
4
Encoder Option
Not required
PG-B3 or PG-X3
Not required
PG-B3 or PG-X3
Not required
for more information about the features of