Keysight A Series User Manual page 490

Hide thumbs Also See for A Series:
Table of Contents

Advertisement

Indoor and Outdoor Mapping – Option 352 (Requires Spectrum Analyzer Mode
(Option 233 on N991xA), and GPS Receiver (Option 307))
How to Set Up Mapping Settings
A KDAT file is the file FieldFox uses to recall an indoor mapping/data
logging session ("Recall Indoor Log File"). It's an archive file that contains
information about the original image file, the location of the recorded data
on the image and the actual recorded data. KDAT files can only be opened
with FieldFox itself. KDAT files cannot be opened via Data Link.
An auxiliary CSV data file is generated automatically, each time a KDAT file
is saved during an indoor mapping session. The CSV contains the recorded
data, without the image, location of the recorded data, etcetera.
3. Press
490
Data Selection
Save
Back
Record Save/Recall
logging filenames and file folder locations
Opens a softkey menu to set the active data
channel, sort type, and sort order.
Channel 1
——
channel being recorded.
Available channels will vary
within each mode.
Sort Power Freq
——
type of measurement
displayed (Power or
Frequency).
Sort Order Up Down
——
the sort order to ascending
(Up) greater
power/frequencies displayed
first or descending (Down)
lowest power or frequency
values displayed first.
Opens a softkey menu to enable you to save your
map (.kdat) or your image (.png).
Save Map
——
log file" where you can name
and save your map file (kDAT).
Softkey is only visible when
data is recorded on a *.png file
using Labels & Icons feature
and the Record softkey.
Save Image (PNG)
——
the current displayed map to a
*.png file (default filename is
"MapImageFile"). This softkey
is on active when View Maps =
O.
Returns to previous softkey menu.
Opens a softkey menu to manage your data
Keysight N9927-90020 User's Guide
- Sets the data
- Sets the
- Sets
- Opens "Save the
- Saves