Section 10
Recording functions
782
Table 564:
DFR Non-group channel settings
Parameter
Values (Range)
Operation
1=Enable
5=Disable
Channel
1)
selection
Channel id text
0 to 64
characters,
alphanumeric
High trigger
0.00...60.00
level
Low trigger
0.00...2.00
level
Storage mode
0=Waveform
1=Trend / cycle
1) Refer to the application manual for channel allocation for each configuration.
Unit
Step
1
0
pu
0.01
pu
0.01
1
1MAC504801-IB E
Default
Description
1=Enable for
Analog
Channels 1 - 4
channel is
5=Disable for
enabled or
channels 5 - 8
disabled
Select the
1)
signal to be
recorded by
this channel.
Applicable
values for this
parameter are
product variant
dependent.
Every product
variant
includes only
the values that
are applicable
to that
particular
variant
DR analog
Identification
channel X
text for the
analog channel
used in the
COMTRADE
format
10.00
High trigger
level for the
analog channel
0.00
Low trigger
level for the
analog channel
0
Storage mode
for the analog
channel
620 series ANSI