Section 6
Supervision functions
6.1.7
Table 420:
52CM Non group settings
Parameter
Values (Range)
Operation
1=enable
5=disable
Acc stop current
5.00...500.00
Open alarm time
0...200
Close alarm time
0...200
Opening time Cor
0...100
Closing time Cor
0...100
Spring charge time
0...60000
Counter initial Val
0...9999
Alarm Op number
0...9999
Lockout Op number
0...9999
Current exponent
0.00...2.00
Difference Cor time
-10...10
Alm Acc currents Pwr
0.00...20000.00
LO Acc currents Pwr
0.00...20000.00
Ini Acc currents Pwr
0.00...20000.00
Directional Coef
-3.00...-0.50
Initial CB Rmn life
0...9999
Rated Op current
100.00...5000.00
Rated fault current
500.00...75000.00
Op number rated
1...99999
Op number fault
1...10000
Life alarm level
0...99999
Pressure alarm time
0...60000
Pres lockout time
0...60000
Inactive Alm days
0...9999
Ini inactive days
0...9999
Inactive Alm hours
0...23
576
Settings
Unit
Step
A
0.01
ms
1
ms
1
ms
1
ms
1
ms
10
1
1
1
0.01
ms
1
0.01
0.01
0.01
0.01
1
A
0.01
A
0.01
1
1
1
ms
1
ms
10
1
1
h
1
Default
Description
1=enable
Operation Disable / Enable
10.00
RMS current setting below which engy acm
stops
40
Alarm level setting for open travel time in ms
40
Alarm level Setting for close travel time in ms
10
Correction factor for open travel time in ms
10
Correction factor for CB close travel time in ms
1000
Setting of alarm for spring charging time of CB
in ms
0
The operation numbers counter initialization
value
200
Alarm limit for number of operations
300
Lock out limit for number of operations
2.00
Current exponent setting for energy calculation
5
Corr. factor for time dif in aux. and main
contacts open time
2500.00
Setting of alarm level for accumulated currents
power
2500.00
Lockout limit setting for accumulated currents
power
0.00
Initial value for accumulation energy (Iyt)
-1.50
Directional coefficient for CB life calculation
5000
Initial value for the CB remaining life
1000.00
Rated operating current of the breaker
5000.00
Rated fault current of the breaker
10000
Number of operations possible at rated current
1000
Number of operations possible at rated fault
current
500
Alarm level for CB remaining life
10
Time delay for gas pressure alarm in ms
10
Time delay for gas pressure lockout in ms
2000
Alarm limit value of the inactive days counter
0
Initial value of the inactive days counter
0
Alarm time of the inactive days counter in hours
1MAC504801-IB E
620 series ANSI
Technical Manual