4. Follow the Install Shield procedure to transfer all the necessary files to the
TN802 IP Interface.
5. Click on Start > Settings > Control Panel > Services.
6. Select IP Trunk and click on Startup.
7. Under Startup Type, select Disabled and click OK to disable IP Trunk
mode.
8. Select MedPro and click on Startup.
9. Under Startup Type, select Automatic and click OK to enable MedPro
mode.
10. Click Start > Shut Down and select Restart the computer?
or on the TN802:
Press the recessed reset button on the faceplate (see
LCD shows a flashing MSHUT *. When the flashing stops and the asterisk
disappears (about 2 min), reseat the circuit pack to restart the system.
or on the SAT:
a. Type busyout board UUCSS and press
b. Type reset board UUCSS and press
c. Type release board UUCSS and press
Once the system is completely initialized, the LCD reads MEDPRO *.
!
555-233-115
NOTE:
In the Finish dialog box, select I will restart later. Do not
select Restart computer.
This would be a good time to read the Readme.txt file.
NOTE:
Do not click on Start.
NOTE:
If IP trunk and MedPro services are both set to automatic, the
TN802B defaults to IP Trunk and MedPro features cannot be used.
NOTE:
Do not click on Start.
WARNING:
When connected remotely via pcANYWHERE, only use the
pcANYWHERE Restart Host Computer button on the toolbar to
restart Windows NT.