Upgrading Release 9/10r to Avaya DEFINITY Server R
running Avaya MultiVantage Software

Check SPE

1. Type status spe and press
Check the health of the SPE.
2. Verify that both tape and disk are in service.
If high or critical reliability:
3. Note the active and standby SPE designations (a/b).
4. Check the following fields:
5. Verify that both tape and disk are in service on both SPEs.
If the fields show something other than the above, see Chapter 4,
"Initialization and Recovery" in Maintenance for Avaya MultiVantage
DEFINITY Server R. Do not continue with the upgrade until all SPE-related
errors are resolved.

Disable TTI

1. Type change system-parameters features and press
2. On the second screen, set the Terminal Translation
Initialization (TTI) Enabled? field to n to de-activate the TTI
feature. If it is already set to n, cancel the command and skip step 3.
3. Type status tti and press
4. Repeat Step 3 until the TTI Background Task State field is
completed.
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.

Save Translations to Disk Drive (pre-upgrade)

1. Type save translation and press
from memory to the disk drive, which takes about 2 minutes.
1-18
Issue 5 October 2002
Enter
The Standby Refreshed? field reads yes.
The Standby Shadowing field reads on.
The Standby Handshake field reads up.
Enter
.
.
to write all translation information
RETURN