Interconnect Port Networks with Fiber Optic Cabling
Fiber-Remoted Port Networks
For a high reliability system with 1 fiber-remoted expansion port network, 2 fiber
optic cables, 2 lightwave transceivers, and 2 lightguide interconnect units
(provided by the PSC) are required.
For a high reliability system with 2 fiber-remoted expansion port networks, 6 fiber
optic cables, 6 lightwave transceivers, and 6 lightguide interconnect units
(provided by the PSC) are required.
For fiber-remoted cabinets, route the cables down the cable tray and out the
bottom of the cabinet to the cross-connect field where the lightguide interconnect
units are located.
In either case, use cable ties to secure the cable against the walls of the cable tray
at the cable tie positions built into the trays.
For Either 1 or 2 Collocated Expansion Port Networks
1. At control carrier A of PPN cabinet 1 (see
2. Behind control carrier A of EPN cabinet 2:
555-233-115
Install a lightwave transceiver on the cable connector at slot 1A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
Connect a fiber optic cable to the transceiver just installed.
Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
Install a lightwave transceiver on the cable connector at slot 2A01.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
Connect the other end of the fiber optic cable to the transceiver just
installed.
Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
At the top of the cabinet, coil the surplus of fiber optic cable and
carefully attach the coil to the wall of the cable tray.
Figure 5-21
through
Figure
Issue 5 October 2002
5-24):
5-105