Avaya DEFINITY Server R Manual page 348

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Adding New Carriers and EPN Cabinets
4. Type save translation and press
After the translations have been copied (about 10 minutes), the system
returns an error code, which must be a zero; otherwise, the translations are
not copied.
5. Type reset system 4 and press
Wait until the system has completely reset before continuing.
6. Type change cabinet 1 and press
In the Carrier Type column change the "B" carrier to processor and
submit the form.
7. Type change system-parameters duplication and press
Set the Enable Operation of SPE Duplication field to y and
submit the form.
8. Type save translation and press
After the translations have been copied (about 10 minutes), the system
returns an error code, which must be a zero; otherwise, the translations are
not copied.
9. Type reset system 3 preserve-license (or reset system 3
no-preserve-license, since the License File has been saved in
translations) and press
10. If the system has IP endpoints registered, and you unplugged the Ethernet
cable from the TN799 (C-LAN) circuit pack, replug the cable.
This re-registers the IP endpoints.
Administer No-License/Emergency Numbers
1. At the SAT type change system-parameters features and press
The Feature-Related System Parameters screen displays.
2. In the Emergency Numbers - Internal field (optional) type a valid
extension.
3. In the Emergency Number - External field (required) type a 21-digit,
dialpad-valid character string that can include trunk access codes. The
default for this field is 911.
4. In the No-License Incoming Call Number field (optional) type a valid
extension.
5. Press
6-28
Issue 5 October 2002
Enter
NOTE:
This number cannot be a hunt group or ACD number.
NOTE:
This number cannot be a hunt group or ACD number.
to save the changes.
ENTER
.
Enter
.
Enter
.
Enter
.
Enter
.
.
Enter
.
RETURN
555-233-115

Advertisement

Table of Contents
loading