Avaya DEFINITY Server R Manual page 463

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Add Multiple Integrated Announcement Circuit Packs
4. Type the circuit pack location in the Slot field (UUCSS). In the example
above the slot is 01C08, meaning Cabinet 1, carrier C, slot 8.
If a TN2501AP circuit pack is not at this location when you submit the
screen, the system prompts you to enter a VAL circuit pack location.
The Node Name field is the same as the one previously administered. (See
change node-names
5. Set the Subnet Mask field according to your network requirements.
6. Gateway Address is usually the same as the TN2501AP circuit pack's IP
address, usually with the fourth octet changed. Be sure to set this address
according to your network requirements.
7. Leave the Net Rgn (Network Region) field at its default value. This field is
not used for VAL.
8. Press
add data-module
Use this command to administer the data module that is associated with the
TN2501AP ethernet port.
1. At the SAT, type add data-module extension/next and press
The Data Module screen appears.
add data-module 30006
Data Extension: 30006
Type: ethernet
Port: 1b0333
Link: 5
Network uses 1's for Broadcast Addresses? y
Screen 7-16. Data Module screen (add data-module extension)
555-233-115
ip)
NOTE:
If you press Help, a list of administered node names appears
(including the name you administered with the change node-names
ip command), and you can select from the list.
to save the changes.
ENTER
DATA MODULE
Name: VAL#2 Data Module
RETURN
Page
1 of
1
SPE A
Issue 5 October 2002
.
7-47