Avaya DEFINITY Server R Manual page 495

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Add IP Solutions
.
change circuit-packs
Cabinet: 1
Slot Code
01: TN754
02: TN758
03: TN2144
04: TN746
05
06: TN771
07: TN464
08: TN2140
09: TN767
10: TN799
'#' indicates circuit pack conflict.
6. If not, type MEDPRO in the slot just above TN802B slot and press
Changing the one entry automatically changes the entry above it. If it is in
IP Trunk mode, you get the following error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
7. Type change ip-interfaces and press
8. Type in the information for the TN802B IP Interface,
9. Set the Enabled field to y, and press
At this time the TN802B LCD reads PC BOOT *, and about 3 to 4 minutes
later reads MEDPRO * with the asterisk flashing
555-233-115
CIRCUIT PACKS
Sf Mode
Name
DIGITAL LINE
POOLED MODEM
ANALOG LINE
B
ANALOG LINE
C
MAINTENANCE/TEST
F
DS1 INTERFACE
E&M TIE TRUNK
E
DS1 INTERFACE
B
CONTROL-LAN
NOTE:
The customer provides the IP address, subnet mask, and gateway
address.
Page
Carrier: A
Carrier Type: processor
Slot Code
Sf Mode
11:
MEDPRO
RESERVED-IP
12:
MEDPRO
RESERVED-IP
13:
TN802
B
14:
15:
16:
.
Enter
.
Enter
Issue 5 October 2002
1 of
5
Name
MAPD BOARD
.
Enter
7-79

Advertisement

Table of Contents
loading

Table of Contents