Avaya DEFINITY Server R Manual page 132

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Upgrading R5si/R6si to an Avaya DEFINITY Server R
EPN running Avaya MultiVantage Software
Required Hardware
The equipment in
Table 4-1. Required Hardware
Equipment
J58890N
Expansion Control Cabinet
108187170
TN775C Maintenance circuit pack
108469446
TN570D Expansion Interface circuit pack
107737934
TN573B Switched Node Interface circuit pack
407439975 or
20-ft. (6 m) Multimode Fiber Optic Cable
407598325
20-ft. (6 m) Single-Mode Fiber Optic Cable
106455348 or
9823A Lightwave Transceiver (short)
106455363 or
9823B Lightwave Transceiver (long)
107731853
300A Lightwave Transceiver (single mode)
J58890to-O L1
Avaya MultiVantage Software on removable media
108773912
TN771DP Maintenance Test circuit pack
846307817
Lower Rear Cover
846307809
Ground Plate
H600-248 G1
ICC Duplication Cables
Earthquake Equipment (if needed):
846408268
Front Panel
846408386
Ground Plate
846408250
Stiffener
846408243
Front Mounting Angle
Attenuators (single-mode fiber only):
106060718
5 dB
106060734
10 dB
106061021
15 dB attenuator (single-mode fiber only)
1.
For each fiber connection, 1 lightwave transceiver is installed in 1 port network, and a like transceiver in the
adjacent port network. 4E transceivers cannot be reused. Additional transceivers, ordered separately, ship loose
with the EPN equipment.
2.
The 300A is connected using 2 fiber optic cables. 5, 10, or 15 dB attenuators may be required.
3.
One removable media is required for a standard reliability system; 2 for a high or critical reliability system.
4.
Depending on the number of EPNs in a critical reliability system.
5.
Required for the B port cabinet of a critical reliability EPN.
6.
Required for a critical reliability EPN.
4-6
Issue 5 October 2002
Table 4-1
must be on-site before the upgrade begins.
Description
Quantity
1
1
Depends on reliability type
and number of PNs
Depends on reliability type
and number of PNs
1 to 12
1
2 to 12
1
2 to 12
2
2 to 12
3
1 or 2
4
1 or 2
5
1
1
6
2
1
1
1
1
2 for each fiber
2
connection
2 for each fiber
2
connection
2 for each fiber
2
connection
555-233-115

Advertisement

Table of Contents
loading

Table of Contents