Avaya DEFINITY Server R Manual page 154

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Upgrading R5si/R6si to an Avaya DEFINITY Server R
EPN running Avaya MultiVantage Software
Reseat DEFINITY LAN Gateway System
1. Reseat the DEFINITY LAN Gateway assembly into the backplane.
Reseat DEFINITY AUDIX System
1. Reseat the DEFINITY AUDIX assembly to its backplane connectors.
Remove Emergency Transfer Ground Wire
1. Remove the ground wire from the emergency transfer unit.
Reboot the System
1. Connect the management terminal or PC to the TERMINAL connector on
the rear of PPN control carrier A.
2. Insert the new Avaya MultiVantage Software on removable media into the
optical drive.
3. Behind each EPN cabinet, set the circuit breaker to ON.
4. At the PPN power distribution unit, set the main circuit breaker to ON.
The system performs a reset level 4 rebooting process, loading blank
translations from the disk. Rebooting takes 5 to 11 minutes.
5. Type reset system 4 and press
a level 4 reboot, loading the upgraded STS translations from the new
removable media. Rebooting takes 5 to 11 minutes.
6. Log in as craft.
7. After about 2 minutes, type status spe and press
Handshake field must show up before continuing with the upgrade.
8. Type reset spe standby 4 and press
to active and vice versa. This takes about 10 minutes.
9. If the system is high or critical reliability, type status spe and press
The Handshake, Refresh, and Shadowing fields show up before
continuing with the upgrade. Also, the standby side field shows
in-service. The heartbeat on the standby SPE flashes yellow.
10. Type restore disk [spe-a or both] full and press
the system to write the upgraded STS translation information from memory
to the disk(s).
4-28
Issue 5 October 2002
. This instructs the system to perform
Enter
. The Standby
Enter
. This changes the standby SPE
Enter
.
Enter
. This instructs
Enter