Install the EPN
Re-record Announcements (TN750/B Only)
1. The off-site STS translation upgrade does not preserve the contents of
recorded announcements. Therefore, if a TN750/B Announcement circuit
pack resides in the system, re-record the announcements that were stored
on the circuit pack.
Administer Fiber Links
1. After all fiber optic equipment is installed, refer to
Administration''.
Re-enable TTI
NOTE:
Do this step only if you disabled TTI before the upgrade.
1. Type change system-parameters features and press
2. On the second screen, set the Terminal Translation
Initialization Enable field to y to re-enable the TTI feature.
3. Type status tti and press
4. Repeat the status command until the TTI Background Task State
reads completed.
Check Link Status
1. Type display communication-interface links and press
with the earlier status.
2. Type status link number and press
Resolve Alarms
1. Type display alarms and press
any alarms that may exist.
555-233-115
NOTE:
Even though a system may have a mixture of TN750/B, TN750C and
TN2501AP announcement/integrated announcement circuit packs,
you do not need to re-record TN750C or TN2501AP integrated
announcements.
Enter
Appendix A, ''Fiber Link
.
. Repeat this step for each link.
Enter
to examine the alarm log. Resolve
Enter
Issue 5 October 2002
.
Enter
. Compare it
Enter
4-35