Upgrading a Multicarrier G2 Universal Module to Avaya
DEFINITY Server R EPN running Avaya MultiVantage
Software
4. Behind control carrier A of EPN cabinet 3:
Figure Notes
1. Cabinet 1 Processor Port Network
2. Cabinet 2 Expansion Port Network 1
Figure 5-15. Standard Reliability with Two or Three Port Networks
5-98
Issue 5 October 2002
Install a lightwave transceiver on cable connector at slot 3A02.
NOTE:
Attenuators may be required for single mode fiber using a
300A Lightwave Transceiver
Connect the other end of the fiber optic cable to the lightwave
transceiver, just installed, at slot 3A02. See
Carefully attach the fiber optic cable (with cable ties) to the wall of
the cable tray at the built-in cable tie positions.
At the top of the cabinet, coil up the surplus fiber optic cable and
attach it to the wall of the cable tray.
Figure
5-18.
3. Cabinet 3 Expansion Port
Network 2