Add a Control Carrier (Add Duplication)
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway.
2. When the main menu appears, select Maintenance.
3. Select Reset System from the Maintenance menu.
4. Select Restart System from the Reset System menu.
Resolve Alarms and Enable Alarm Origination
1. Examine the alarm log. Resolve any alarms.
2. If the Alarm Origination Activated field administration is already
set to y, be sure to enable Alarm Origination. Otherwise you do not need to
enable Alarm Origination (proceed to the next section).
3. Type change system-parameters maintenance and press
The Alarm Origination Activated field was changed to Alarm
Origination to OSS Numbers to support more than 1 OSS.
4. Type first-only in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to enter y in both Cleared Alarm Notification and
Restart Notification fields. Press
5. Type save translation spe-a disk and press
!
WARNING:
If you do not enable Alarm Origination when the customer has purchased a
services contract, the switch will not report any alarm to the TSC
automatically, causing the TSC to be unable to fulfill the services contract.
Register the Switch for Maintenance
The Automatic Registration Tool (ART) is a web-based tool that permits field
technicians and TSO Database Administration (DBA) to register U.S. direct
channel products.
The product that you are registering must have switch connectivity through:
the INADS line
an IP address
NOTE:
ART is not accessible from the public internet (outside the Avaya intranet
firewall).