Avaya DEFINITY Server R Manual page 534

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Fiber Link Administration
The following DS1 Converter Complex fields appear on Page 2 when the Is one
endpoint remoted via a DS1 Converter Complex field is y.
NOTE:
When you administer DS1 Converter TN1654 circuit packs, different fields
display.
DS1CONV Board Location
identifies the physical location of the converter circuit pack connected to
the first endpoint of the fiber link. This is entered on Page 1 and displays on
Page 2.
DS1CONV Board Type
Converter circuit pack for the first endpoint.
DS1CONV Board Location
identifies the physical location of the converter circuit pack connected to
the second endpoint of the fiber link.
DS1CONV Board Type
Converter circuit pack for the second endpoint. This field is updated via the
Change Circuit-packs command.
Facility Installed
Converter Facilities heading to indicate that this DS1 facility is physically
installed. At least facility A must be installed within the converter complex.
Default is yes for Facility A.
Passes Far-end Clock
the DS1 Converter Facilities heading to indicate that this DS1 facility is
suitable to be used as a clock source. If the DS1 signal does not come
directly from the far end converter circuit pack or the network (such as
when the signal is converted from digital to analog and then back to digital),
enter "no." Default is yes for Facility A.
This field determines whether the DS1 converter circuit pack can use
receive DS1 signal timing to time the transmit fiber signal. This is
necessary for passing timing from a master PN to a slave PN across a
Converter Complex.
Digital Data Compatible
columns under the DS1 Converter Facilities heading to indicate that this
DS1 facility is suitable for transmission of digital data. At least Facility A
must be suitable for transmission of digital data. If Customer Premises
Equipment that alters digital data exists on this facility (such as with a
channel expansion multiplexer), enter no.
A-12
Issue 5 October 2002
Enter the cabinet, carrier, and slot that
Display-only field showing the type of DS1
Enter the cabinet, carrier, and slot that
Display-only field showing the type of DS1
Enter yes in the B, C, and D columns under the DS1
Enter "yes" in the B, C, and D columns under
Enter yes (default) in the B, C, and D
555-233-115

Advertisement

Table of Contents
loading

Table of Contents