Add MCC Port Carriers
4. Type first-only in this field to enable Alarm Origination (to the first OSS,
which should be INADS).
Be sure to type y in both Cleared Alarm Notification and Restart
Notification fields. Press
!
Save Translations
1. If the system is high- or critical-reliability, type status spe and press
verify that the standby SPE is refreshed and that the standby disk is in
service.
2. Type save translation [spe-a or both] disk and press
command instructs the system to take all translation information in memory
and write it to the disk(s).
3. If the MCC port network contains a TN750 Announcement circuit pack,
type list configuration software-version and press
If screen 2 shows that recorded announcements were saved, these
announcements can be restored using the restore announcements
command. Type restore announcements and press
4. Type backup disk [spe-a or both] and press
the system to backup the current information on disk to the removable
media.
555-233-115
NOTE:
The INADS Database Administrator enables Alarm Origination as
part of the registration process.
CAUTION:
If you do not enable Alarm Origination when the customer has
purchased a services contract, the switch will not report any alarm to
the TSC automatically, causing the TSC to be unable to fulfill the
services contract.
.
Enter
. This command instructs
Enter
Issue 5 October 2002
to
Enter
. This
Enter
.
Enter
.
Enter
6-7