Avaya DEFINITY Server R Manual page 525

Upgrades and additions
Hide thumbs Also See for DEFINITY Server R:
Table of Contents

Advertisement

Administer Fiber Links
c. Scroll to page 2 of the form. Enter y as applicable, in each
d. In the Bit Rate: field, type either 1.544 (T1) or 2.048 (E1).
e. Enter the idle code in the Idle Code MSB (1) . . . . LSB
f. In the Line Coding: field, enter the line coding information. This
5. For T1 sites, refer to
Installations
T1 Installations Only
1. The Framing Mode: field is display only and shows the hardware setting.
2. The DS1CONV-1 Line Compensation: and the DS1CONV-2 Line
Compensation: fields are display only and show the hardware setting.
3. In the Facility A Circuit ID: field, enter an optional facility name
that is unique to each facility (up to 40 alphanumeric characters). Press
Enter
4. A display similar to the following appears after the fiber link administration
is completed:
RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.
E1 Installations Only
1. Type y or n in the CRC? field. The "CRC" means Cyclic Redundancy
Check. This is an error detection algorithm.
2. The Line Termination: field is display only. A 75 (75 Ohms) or 120
(120 Ohms) typically displays.
3. In the Facility A Circuit ID: field, enter an optional facility name
that is unique to each facility (up to 40 alphanumeric characters). Press
Enter
4. A display similar to the following appears after the fiber link administration
is completed:
RESET PORT-NETWORK 2 LEVEL 2 (COLD) PERFORMED.
555-233-115
Facility Installed? field (A, B, C, and D).
(8): field. The default value is 11101000. It is recommended that
the default value be used unless it becomes absolutely necessary to
change it. The "MSB" means Most Significant Bit, the "LSB" means
Least Significant Bit.
information should match the line coding of the facility. For T1,
example line coding is b8zs. For E1, example line coding is hdb3.
NOTE:
If this data is not correct, wideband errors (multimedia call
handling) may occur.
''T1 Installations
Only''.
.
.
Only''. For E1 sites, refer to
Issue 5 October 2002
''E1